Publication: Aortic rupture following an EVAR secondary to graft erosion
Loading...
Date
2016
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
Significant type 3 endoleak as a defect in the graft material, especially associated with endograft rupture, is a rare complication. A 68-year-old male patient with aortic plaque rupture was treated with endovascular graft placement. The patient was readmitted two years later with severe abdominal pain, a large retroperitoneal hematoma and contrast extravasation below the location where the aortic plaque had presented. Before an aortic infrarenal cuff could be placed during a control angiography, a large graft hole and a significant type 3 endoleak were observed. The sharp aortic plaque may have been responsible for the endograft tear. © 2015 Wiley Periodicals, Inc.
Description
Keywords
aortic plaque, endograft rupture, Type 3 endoleak