Publication:
Balloon angioplasty of cardiac vein in a patient treated by cardiac resynchronization therapy

dc.contributor.authorDjuric, Predrag (52163459400)
dc.contributor.authorMladenovic, Zorica (57219652992)
dc.contributor.authorDrobnjak, Dragan (56461183100)
dc.contributor.authorSpasic, Marijan (56157463900)
dc.contributor.authorJovic, Zoran (35366610200)
dc.contributor.authorDjuric, Ivica (55676578600)
dc.contributor.authorBogdanovic, Predrag (56461299200)
dc.contributor.authorRomanovic, Radoslav (6602427698)
dc.contributor.authorMilašinovic, Goran (9238319300)
dc.date.accessioned2025-06-12T13:44:12Z
dc.date.available2025-06-12T13:44:12Z
dc.date.issued2021
dc.description.abstractIntroduction. Cardiac resynchronization therapy (CRT) reduces mortality and hospitalization in patients with symptomatic heart failure and left bundle branch block (LBBB) on optimal drug therapy. Among all, the reasons for "non-response" to CRT pacemaker could be the fail-ure to achieve optimal left ventricular (LV) lead position due to severe curve or stenosis/occlusion of the target vein. Case report. We presented a 79-old-male patient, New York Heart Association (NYHA) class III, with atrial fibrillation, chronic coronary syndrome (CCS), and prior myocardial infarction. The patient underwent coro-nary artery bypass surgery and mechanical prosthetic aor-tic valve implantation. He was indicated for CRT. The patient's venogram revealed ostial/proximal severe curve and stenosis of the posterolateral vein, the only vein of coronary sinus that led to anatomically optimal LV seg-ment for stimulation. After the balloon angioplasty of the curved and stenotic portion of the target vein with compliant balloon 4.0 × 30 mm, a satisfactory and stable position of quadripolar LV lead was achieved. Conclu-sion. Compliant balloon angioplasty could be a safe and efficient way to override severe coronary vein stenosis in some CRT cases. © 2021 Inst. Sci. inf., Univ. Defence in Belgrade. All rights reserved.
dc.identifier.urihttps://doi.org/10.2298/VSP200508061D
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85121644980&doi=10.2298%2fVSP200508061D&partnerID=40&md5=d21d22cc1788fa065ac345c06f89691b
dc.identifier.urihttps://remedy.med.bg.ac.rs/handle/123456789/4407
dc.subjectAngioplasty, balloon
dc.subjectCardiac resynchronization therapy
dc.subjectCoronary sinus
dc.subjectHeart failure
dc.titleBalloon angioplasty of cardiac vein in a patient treated by cardiac resynchronization therapy
dspace.entity.typePublication

Files