Publication:
Evaluation of the Limb Symmetry Index: The Side Hop Test

dc.contributor.authorMirković, Sanja V. (57266545000)
dc.contributor.authorĐurić, Saša (56577831600)
dc.contributor.authorSember, Vedrana (57192155860)
dc.contributor.authorKnezevic, Olivera M. (37063293000)
dc.contributor.authorPajek, Maja (55147927200)
dc.contributor.authorMirković, Milan M. (57190251388)
dc.contributor.authorMirkov, Dragan M. (6508073239)
dc.date.accessioned2025-06-12T12:51:27Z
dc.date.available2025-06-12T12:51:27Z
dc.date.issued2022
dc.description.abstractThe main objective of present study was to evaluate inter-rater reliability and concurrent validity of Side Hop Test stopwatch vs. force plates timing, and to determine the number of sessions and trials required to minimize the effects of learning on Side Hop Test total time and limb symmetry index. Fifteen healthy male physical education students (mean ± SD: age, 23 ± 3 years; height, 181 ± 9 cm; and weight 72 ± 6 kg) participated. Side Hop Test total time (stopwatch and force plates) of left and right leg, and limb symmetry index (force plates) were obtained over seven sessions conducted 5–7 days apart. Time recordings of two raters were similar (t = −0.56, p > 0.05) with high reliability (all ICC >0.99 and CV% <0.1) and no systematic bias when compared to force plate data (p > 0.05; for rater 1 and 2, respectively). Total time improved across the Sessions (F = 25.87, p < 0.01, ω2 = 0.18) and Trials (F = 68.15, p < 0.01, ω2 = 0.10), with no significant interaction between factors. No between-leg differences were detected (F = 0.52, p > 0.05, ω2 = 0.001). Limb symmetry index ranged from 0.999 to 1.055 across all sessions and trials (all p > 0.05 and ω2 < 0.00). Due to low coefficient of correlation, high interclass correlation coefficient, and the lack in heteroscedasticity, stopwatch measurements are valid to measure total time in the Side Hop Test. Moreover, stopwatch measurements could be reliably used to measure total time in the Side Hop Test, while the test could be administrated with only one experienced rater. Unlike total times, findings on limb symmetry index suggest it could be reliably assessed after seven familiarization sessions. Copyright © 2022 Mirković, Đurić, Sember, Knezevic, Pajek, Mirković and Mirkov.
dc.identifier.urihttps://doi.org/10.3389/fphys.2022.874632
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85134074565&doi=10.3389%2ffphys.2022.874632&partnerID=40&md5=23ac3c5029d5a96972b0686d91aa9ea0
dc.identifier.urihttps://remedy.med.bg.ac.rs/handle/123456789/3534
dc.subjectconcurrent validity
dc.subjectlimb symmetry index
dc.subjectreliability
dc.subjectside hop test
dc.subjectstopwatch
dc.titleEvaluation of the Limb Symmetry Index: The Side Hop Test
dspace.entity.typePublication

Files