Browsing by Author "van Pesch, V. (15847200900)"
Now showing 1 - 2 of 2
- Results Per Page
- Sort Options
- Some of the metrics are blocked by yourconsent settings
Publication Kappa free light chains is a valid tool in the diagnostics of MS: A large multicenter study(2020) ;Leurs, C.E. (56866079400) ;Twaalfhoven, H.A.M. (26533533200) ;Lissenberg-Witte, B.I. (57204744042) ;van Pesch, V. (15847200900) ;Dujmovic, I. (6701590899) ;Drulovic, J. (55886929900) ;Castellazzi, M. (57190160648) ;Bellini, T. (7004337741) ;Pugliatti, M. (6603827112) ;Kuhle, J. (8937520800) ;Villar, L.M. (35518965300) ;Alvarez-Cermeño, J.C. (7004605927) ;Alvarez-Lafuente, R. (13411081600) ;Hegen, H. (57202373490) ;Deisenhammer, F. (7004758773) ;Walchhofer, L.M. (57194580116) ;Thouvenot, E. (35325407800) ;Comabella, M. (6701491362) ;Montalban, X. (7007177960) ;Vécsei, L. (35452449900) ;Rajda, C. (6603645376) ;Galimberti, D. (6701617660) ;Scarpini, E. (57210771033) ;Altintas, A. (7006317905) ;Rejdak, K. (8284992700) ;Frederiksen, J.L. (7102315536) ;Pihl-Jensen, G. (56568478300) ;Jensen, P.E.H. (57214664093) ;Khalil, M. (55628524072) ;Voortman, M.M. (57195917900) ;Fazekas, F. (7102945505) ;Saiz, A. (56213393300) ;La Puma, D. (56422282100) ;Vercammen, M. (6602461163) ;Vanopdenbosch, L. (6602558181) ;Uitdehaag, B.M.J. (57243388200) ;Killestein, J. (7004423164) ;Bridel, C. (6508071655)Teunissen, C. (6701704380)Objective: To validate kappa free light chain (KFLC) and lambda free light chain (LFLC) indices as a diagnostic biomarker in multiple sclerosis (MS). Methods: We performed a multicenter study including 745 patients from 18 centers (219 controls and 526 clinically isolated syndrome (CIS)/MS patients) with a known oligoclonal IgG band (OCB) status. KFLC and LFLC were measured in paired cerebrospinal fluid (CSF) and serum samples. Gaussian mixture modeling was used to define a cut-off for KFLC and LFLC indexes. Results: The cut-off for the KFLC index was 6.6 (95% confidence interval (CI) = 5.2–138.1). The cut-off for the LFLC index was 6.9 (95% CI = 4.5–22.2). For CIS/MS patients, sensitivity of the KFLC index (0.88; 95% CI = 0.85–0.90) was higher than OCB (0.82; 95%CI = 0.79–0.85; p < 0.001), but specificity (0.83; 95% CI = 0.78–0.88) was lower (OCB = 0.92; 95% CI = 0.89–0.96; p < 0.001). Both sensitivity and specificity for the LFLC index were lower than OCB. Conclusion: Compared with OCB, the KFLC index is more sensitive but less specific for diagnosing CIS/MS. Lacking an elevated KFLC index is more powerful for excluding MS compared with OCB but the latter is more important for ruling in a diagnosis of CIS/MS. © The Author(s), 2019. - Some of the metrics are blocked by yourconsent settings
Publication Kappa free light chains is a valid tool in the diagnostics of MS: A large multicenter study(2020) ;Leurs, C.E. (56866079400) ;Twaalfhoven, H.A.M. (26533533200) ;Lissenberg-Witte, B.I. (57204744042) ;van Pesch, V. (15847200900) ;Dujmovic, I. (6701590899) ;Drulovic, J. (55886929900) ;Castellazzi, M. (57190160648) ;Bellini, T. (7004337741) ;Pugliatti, M. (6603827112) ;Kuhle, J. (8937520800) ;Villar, L.M. (35518965300) ;Alvarez-Cermeño, J.C. (7004605927) ;Alvarez-Lafuente, R. (13411081600) ;Hegen, H. (57202373490) ;Deisenhammer, F. (7004758773) ;Walchhofer, L.M. (57194580116) ;Thouvenot, E. (35325407800) ;Comabella, M. (6701491362) ;Montalban, X. (7007177960) ;Vécsei, L. (35452449900) ;Rajda, C. (6603645376) ;Galimberti, D. (6701617660) ;Scarpini, E. (57210771033) ;Altintas, A. (7006317905) ;Rejdak, K. (8284992700) ;Frederiksen, J.L. (7102315536) ;Pihl-Jensen, G. (56568478300) ;Jensen, P.E.H. (57214664093) ;Khalil, M. (55628524072) ;Voortman, M.M. (57195917900) ;Fazekas, F. (7102945505) ;Saiz, A. (56213393300) ;La Puma, D. (56422282100) ;Vercammen, M. (6602461163) ;Vanopdenbosch, L. (6602558181) ;Uitdehaag, B.M.J. (57243388200) ;Killestein, J. (7004423164) ;Bridel, C. (6508071655)Teunissen, C. (6701704380)Objective: To validate kappa free light chain (KFLC) and lambda free light chain (LFLC) indices as a diagnostic biomarker in multiple sclerosis (MS). Methods: We performed a multicenter study including 745 patients from 18 centers (219 controls and 526 clinically isolated syndrome (CIS)/MS patients) with a known oligoclonal IgG band (OCB) status. KFLC and LFLC were measured in paired cerebrospinal fluid (CSF) and serum samples. Gaussian mixture modeling was used to define a cut-off for KFLC and LFLC indexes. Results: The cut-off for the KFLC index was 6.6 (95% confidence interval (CI) = 5.2–138.1). The cut-off for the LFLC index was 6.9 (95% CI = 4.5–22.2). For CIS/MS patients, sensitivity of the KFLC index (0.88; 95% CI = 0.85–0.90) was higher than OCB (0.82; 95%CI = 0.79–0.85; p < 0.001), but specificity (0.83; 95% CI = 0.78–0.88) was lower (OCB = 0.92; 95% CI = 0.89–0.96; p < 0.001). Both sensitivity and specificity for the LFLC index were lower than OCB. Conclusion: Compared with OCB, the KFLC index is more sensitive but less specific for diagnosing CIS/MS. Lacking an elevated KFLC index is more powerful for excluding MS compared with OCB but the latter is more important for ruling in a diagnosis of CIS/MS. © The Author(s), 2019.