Browsing by Author "Zlatanovic, Marko (36661583700)"
Now showing 1 - 3 of 3
- Results Per Page
- Sort Options
- Some of the metrics are blocked by yourconsent settings
Publication Ganglion Cell-Inner Plexiform Layer Thickness in Different Glaucoma Stages Measured by Optical Coherence Tomography(2018) ;Zivkovic, Maja (54958230800) ;Dayanir, Volkan (6603029661) ;Zlatanovic, Marko (36661583700) ;Zlatanovic, Gordana (16837679100) ;Jaksic, Vesna (23667666000) ;Jovanovic, Predrag (55509641300) ;Radenkovic, Marija (36087942700) ;Djordjevic-Jocic, Jasmina (15753565200) ;Stankovic-Babic, Gordana (27868127800)Jovanovic, Svetlana (54391267300)Aim: To compare ganglion cell (GCL) and inner plexiform layer (IPL) thickness in patients at different stages of primary open-angle glaucoma (POAG), determine their sensitivity and specificity values, and correlate thickness values with mean deviations (MD). Methods: This prospective, cross- sectional study was conducted in a group of patients with confirmed POAG who were compared to an age- and gender-matched control group. Glaucomatous damage was classified according to the Hodapp-Parrish-Anderson scale: glaucoma stage 1 (early), glaucoma stage 2 (moderate), and glaucoma stage 3 (severe). The average, minimum, and all 6 sectoral (superotemporal, superior, superonasal, inferonasal, inferior, and inferotemporal) GCL + IPL thicknesses were measured and compared between groups. Results: The average GCL + IPL thickness of 154 eyes of 93 patients in glaucoma stages 1, 2, 3, and 94 eyes of 47 persons in the control group were 76.79 ± 8.05, 65.90 ± 7.92, 57.38 ± 10.00, and 86.01 ± 3.68 μm, respectively. There were statistically significant differences in the average, minimum, and all 6 sectoral GCL + IPL values among the groups. The areas under the receiver operating characteristic curve for average and minimum GCL + IPL thickness values were 0.93 and 0.94, respectively, sensitivity 91.5 and 88.3%, and specificity 98.9 and 100%, respectively. Both thickness values showed significant correlations with MD. Each micrometer decrease in the average GCL + IPL thickness was associated with a 0.54-dB loss in MD. Conclusion: GCL + IPL layer thickness is a highly specific and sensitive parameter in differentiating glaucomatous from healthy eyes showing progressive damage as glaucoma worsens. Loss of this layer is highly correlated with overall loss of visual field sensitivity. © 2017 S. Karger AG, Basel. Copyright: All rights reserved. - Some of the metrics are blocked by yourconsent settings
Publication Ganglion Cell-Inner Plexiform Layer Thickness in Different Glaucoma Stages Measured by Optical Coherence Tomography(2018) ;Zivkovic, Maja (54958230800) ;Dayanir, Volkan (6603029661) ;Zlatanovic, Marko (36661583700) ;Zlatanovic, Gordana (16837679100) ;Jaksic, Vesna (23667666000) ;Jovanovic, Predrag (55509641300) ;Radenkovic, Marija (36087942700) ;Djordjevic-Jocic, Jasmina (15753565200) ;Stankovic-Babic, Gordana (27868127800)Jovanovic, Svetlana (54391267300)Aim: To compare ganglion cell (GCL) and inner plexiform layer (IPL) thickness in patients at different stages of primary open-angle glaucoma (POAG), determine their sensitivity and specificity values, and correlate thickness values with mean deviations (MD). Methods: This prospective, cross- sectional study was conducted in a group of patients with confirmed POAG who were compared to an age- and gender-matched control group. Glaucomatous damage was classified according to the Hodapp-Parrish-Anderson scale: glaucoma stage 1 (early), glaucoma stage 2 (moderate), and glaucoma stage 3 (severe). The average, minimum, and all 6 sectoral (superotemporal, superior, superonasal, inferonasal, inferior, and inferotemporal) GCL + IPL thicknesses were measured and compared between groups. Results: The average GCL + IPL thickness of 154 eyes of 93 patients in glaucoma stages 1, 2, 3, and 94 eyes of 47 persons in the control group were 76.79 ± 8.05, 65.90 ± 7.92, 57.38 ± 10.00, and 86.01 ± 3.68 μm, respectively. There were statistically significant differences in the average, minimum, and all 6 sectoral GCL + IPL values among the groups. The areas under the receiver operating characteristic curve for average and minimum GCL + IPL thickness values were 0.93 and 0.94, respectively, sensitivity 91.5 and 88.3%, and specificity 98.9 and 100%, respectively. Both thickness values showed significant correlations with MD. Each micrometer decrease in the average GCL + IPL thickness was associated with a 0.54-dB loss in MD. Conclusion: GCL + IPL layer thickness is a highly specific and sensitive parameter in differentiating glaucomatous from healthy eyes showing progressive damage as glaucoma worsens. Loss of this layer is highly correlated with overall loss of visual field sensitivity. © 2017 S. Karger AG, Basel. Copyright: All rights reserved. - Some of the metrics are blocked by yourconsent settings
Publication Influence of Multiple Anti-VEGF Injections on Retinal Nerve Fiber Layer and Ganglion Cell-Inner Plexiform Layer Thickness in Patients with Exudative Age-Related Macular Degeneration(2023) ;Zivkovic, Maja (54958230800) ;Radosavljevic, Aleksandra (56993158000) ;Zlatanovic, Marko (36661583700) ;Jaksic, Vesna (23667666000) ;Davidovic, Sofija (20435452600) ;Stamenkovic, Miroslav (7003436370) ;Todorovic, Ivana (57578120000)Jaksic, Jana (58077377100)Backgrounds and Objectives: To analyze the influence of multiple anti-VEGF intravitreal injections for exudative age-related macular degeneration on the thickness of peripapillary retinal nerve fiber layer (RNFL) and macular ganglion cell-inner plexiform layer (GC + IPL) using spectral domain optical coherence tomography (SD-OCT). Materials and Methods: A prospective interventional study of consecutive patients treated with intravitreal bevacizumab (IVB) was performed. Average and sectorial values of RNFL and GC + IPL thickness were recorded using Cirrus SD-OCT at 0, 6, 12, and 24 months. Patients suffering from any ocular disease that could affect RNFL or GC + IPL thickness were excluded. Results: A total of 135 patients (70 women and 65 men, aged 65 ± 15 years) were included. The average number of injections per patient was 12.4 ± 2.4. Average RNFL and GC + IPL thickness prior to the first injection (87.6 ± 12.2 and 47.2 ± 15.5 respectively), and after 24-month follow-up (86.2 ± 12.6 and 46.7 ± 11.9 respectively) did not differ significantly (p > 0.05). There was a significant decrease in GC2, GC5 segments, and minimum GC + IPL thickness. Conclusion: Repeated anti-VEGF treatment did not cause significant changes in the thickness of RNFL and GC + IPL layers over a period of 24 months. The detected decrease in GC2 and GC5 sectors, as well as in minimum GC + IPL thickness, could be a sign of ganglion cell damage induced by the treatment or could occur during the natural course of the disease. © 2023 by the authors.
