Repository logo
  • English
  • Srpski (lat)
  • Српски
Log In
Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "Yang, Junqing (54792452400)"

Filter results by typing the first few letters
Now showing 1 - 1 of 1
  • Results Per Page
  • Sort Options
  • Loading...
    Thumbnail Image
    Some of the metrics are blocked by your 
    consent settings
    Publication
    Dynamic assessment of the left main-left circumflex bending angle: Implications for ostial left circumflex artery in-stent restenosis after successful two-stent PCI
    (2023)
    Wang, Zhiqing (56415976400)
    ;
    Yang, Junqing (54792452400)
    ;
    Li, Chunming (57222227112)
    ;
    Huang, Jiayue (57201477168)
    ;
    Fezzi, Simone (57218421704)
    ;
    Chen, En (57208253773)
    ;
    Cai, Wei (42661093300)
    ;
    Stankovic, Goran (59150945500)
    ;
    Wijns, William (7006420435)
    ;
    Chen, Lianglong (26663007800)
    ;
    Tu, Shengxian (24479856500)
    Background: Two-stent techniques for percutaneous coronary intervention (PCI) on left main (LM) bifurcation (LMB) lesions are associated with an increased risk of in-stent restenosis (ISR) at left circumflex artery (LCx) ostium but the underlying mechanisms are incompletely understood. This study sought to investigate the association between cyclic change of LM-LCx bending angle (BALM-LCx) and the risk of ostial LCx ISR following two-stent techniques. Methods: In a retrospective cohort of patients undergoing two-stent PCI for LMB lesions, BALM-LCx and distal bifurcation angle (DBA) were computed with 3-dimensional angiographic reconstruction. The analysis was performed both at end-diastole and end-systole, and the angulation change throughout the cardiac cycle was defined as the cardiac motion-induced angulation change (∆CAngle). Results: A total of 101 patients were included. The mean pre-procedural BALM-LCx was 66.8 ± 16.1° at end-diastole and 54.1 ± 13.3° at end-systole with a range of 13.0 ± 7.7°. Pre-procedural ∆CBALM-LCx > 16.4° was the most relevant predictor of ostial LCx ISR (adjusted OR 11.58, 95% CI 4.04–33.19; p < 0.001). Post-procedural ∆CBALM-LCx > 9.8° and stent-induced diastolic BALM-LCx change > 11.6° were also related with ostial LCx ISR. DBA was positively correlated with BALM-LCx and showed a weaker association of pre-procedural ∆CDBA > 14.5° with ostial LCx ISR (adjusted OR 6.87, 95% CI 2.57–18.37; p < 0.001). Conclusions: Three-dimensional angiographic bending angle is a feasible and reproducible novel method for LMB angulation measurement. A large pre-procedural cyclic change of BALM-LCx was associated with an increased risk of ostial LCx ISR following two-stent techniques. © 2023 Elsevier B.V.

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Privacy policy
  • End User Agreement
  • Send Feedback