Browsing by Author "Vrolix, Mathias (9437101100)"
Now showing 1 - 2 of 2
- Results Per Page
- Sort Options
- Some of the metrics are blocked by yourconsent settings
Publication A first-in-man clinical evaluation of Ultimaster, a new drugeluting coronary stent system: CENTURY study(2015) ;Barbato, Emanuele (58118036500) ;Salinger-Martinovic, Sonja (15052251700) ;Sagic, Dragan (35549772400) ;Beleslin, Branko (6701355424) ;Vrolix, Mathias (9437101100) ;Neskovic, Aleksandar N. (35597744900) ;Jagic, Nikola (11641086000) ;Verheye, Stefan (6701468632) ;Mehmedbegovic, Zlatko (55778381000)Wijns, William (7006420435)Aims: To report the six-month angiographic and two-year clinical outcome data from the first-in-man study with the Ultimaster DES, a thin-strut cobalt-chromium sirolimus-eluting stent (SES) with an innovative abluminal-gradient-coated bioresorbable polymer. Methods and results: CENTURY is a multicentre, single-arm, prospective study that enrolled 105 patients (113 lesions) with coronary artery disease. All patients were scheduled to have an angiographic follow-up at six months, while 45 and 20 patients respectively had IVUS and OCT assessments. The primary endpoint was six-month in-stent late lumen loss. Secondary endpoints included clinical, IVUS and OCT outcomes. Clinical follow-up is available up to two years and will continue up to five years. Procedural success was 97.1% and device success was 100%. Angiographic late loss at six months was 0.04±0.35 mm, also reflected in a low binary restenosis rate of 0.9% and confirmed by IVUS-assessed neointimal volume obstruction of 1.02±1.62%. The mean strut coverage assessed by OCT was 96.2% with 1.66±4.02 malapposed stent struts. There were no deaths in the study, three (2.9%) periprocedural and one (0.9%) spontaneous myocardial infarction, not related to the target vessel. At one and two years, the target lesion failure rate was 3.8% and 5.7%, while the TLR rate was 1.9% and 2.8%, respectively. There was one acute definite stent thrombosis. Conclusions: The Ultimaster™ novel bioresorbable polymer sirolimus-eluting stent demonstrated good performance, including high procedural success and strong suppression of neointimal proliferation at six months. Good safety and effectiveness were shown up to two years in the studied population. © Europa Digital & Publishing 2015. All rights reserved. - Some of the metrics are blocked by yourconsent settings
Publication Cardiopoietic stem cell therapy in heart failure: The C-CURE (cardiopoietic stem cell therapy in heart failURE) multicenter randomized trial with lineage-specified biologics(2013) ;Bartunek, Jozef (7006397762) ;Behfar, Atta (6602328079) ;Dolatabadi, Dariouch (6508388377) ;Vanderheyden, Marc (7003468696) ;Ostojic, Miodrag (34572650500) ;Dens, Jo (6603775734) ;El Nakadi, Badih (6603603243) ;Banovic, Marko (33467553500) ;Beleslin, Branko (6701355424) ;Vrolix, Mathias (9437101100) ;Legrand, Victor (7005354273) ;Vrints, Christian (35452176900) ;Vanoverschelde, Jean Louis (19336371400) ;Crespo-Diaz, Ruben (24490651400) ;Homsy, Christian (36910179100) ;Tendera, Michal (7005482361) ;Waldman, Scott (7102179927) ;Wijns, William (7006420435)Terzic, Andre (7004939597)Objectives This study sought to evaluate the feasibility and safety of autologous bone marrow-derived and cardiogenically oriented mesenchymal stem cell therapy and to probe for signs of efficacy in patients with chronic heart failure. Background In pre-clinical heart failure models, cardiopoietic stem cell therapy improves left ventricular function and blunts pathological remodeling. Methods The C-CURE (Cardiopoietic stem Cell therapy in heart failURE) trial, a prospective, multicenter, randomized trial, was conducted in patients with heart failure of ischemic origin who received standard of care or standard of care plus lineage-specified stem cells. In the cell therapy arm, bone marrow was harvested and isolated mesenchymal stem cells were exposed to a cardiogenic cocktail. Derived cardiopoietic stem cells, meeting release criteria under Good Manufacturing Practice, were delivered by endomyocardial injections guided by left ventricular electromechanical mapping. Data acquisition and analysis were performed in blinded fashion. The primary endpoint was feasibility/safety at 2-year follow-up. Secondary endpoints included cardiac structure/function and measures of global clinical performance 6 months post-therapy. Results Mesenchymal stem cell cocktail-based priming was achieved for each patient with the dose attained in 75% and delivery without complications in 100% of cases. There was no evidence of increased cardiac or systemic toxicity induced by cardiopoietic cell therapy. Left ventricular ejection fraction was improved by cell therapy (from 27.5 ± 1.0% to 34.5 ± 1.1%) versus standard of care alone (from 27.8 ± 2.0% to 28.0 ± 1.8%, p < 0.0001) and was associated with a reduction in left ventricular end-systolic volume (-24.8 ± 3.0 ml vs. -8.8 ± 3.9 ml, p < 0.001). Cell therapy also improved the 6-min walk distance (+62 ± 18 m vs. -15 ± 20 m, p < 0.01) and provided a superior composite clinical score encompassing cardiac parameters in tandem with New York Heart Association functional class, quality of life, physical performance, hospitalization, and event-free survival. Conclusions The C-CURE trial implements the paradigm of lineage guidance in cell therapy. Cardiopoietic stem cell therapy was found feasible and safe with signs of benefit in chronic heart failure, meriting definitive clinical evaluation. (C-Cure Clinical Trial; NCT00810238). © 2013 by the American College of Cardiology Foundation.
