Browsing by Author "Seric, Srdjan (54880261200)"
Now showing 1 - 4 of 4
- Results Per Page
- Sort Options
- Some of the metrics are blocked by yourconsent settings
Publication Lower extremity lipedema, upper extremity lipodystrophy and severe calcinosis complicating juvenile dermatomyositis(2014) ;Pavlov-Dolijanovic, Slavica R. (8452470400) ;Vujasinovic Stupar, Nada Z. (24831218300) ;Gavrilov, Nikola (54879613200)Seric, Srdjan (54880261200)Juvenile dermatomyositis (JDM) is a rare but complex and potentially life-threatening autoimmune disease of childhood. Significant proportions of patients have residual weakness, muscle atrophy, joint contractures, and calcinosis. Recently, new clinical findings, such as lipodystrophy accompanied with increased fat deposition in certain areas, have been reported. So far, it is not known whether the redistribution of body fat may be the type of lipedema of lower extremity. We describe a 39-year-old woman who was diagnosed with JDM at the age of 7. Later she developed symmetrical lipodystrophy of upper extremities and symmetrical lipedema of lower extremities (making 2 and 58.3 % of total body fat mass, respectively), with multiple calcified nodules in the subcutaneous tissues. These nodules gradually increased in size despite therapy. Capillaroscopy findings showed scleroderma-like abnormalities. ANA and anti-U1RNP antibodies were positive. Similar cases with simultaneous occurrence of the lipedema of lower extremities, lipodystrophy of upper extremities, and severe calcinosis complicating JDM have not been published so far. We showed that the calcinosis and lipodystrophy were associated with short duration of active disease. Also, we display case that raises the question whether it is possible overlapping autoimmune diseases revealed during follow-up. © 2014, Springer-Verlag Berlin Heidelberg. - Some of the metrics are blocked by yourconsent settings
Publication Lower extremity lipedema, upper extremity lipodystrophy and severe calcinosis complicating juvenile dermatomyositis(2014) ;Pavlov-Dolijanovic, Slavica R. (8452470400) ;Vujasinovic Stupar, Nada Z. (24831218300) ;Gavrilov, Nikola (54879613200)Seric, Srdjan (54880261200)Juvenile dermatomyositis (JDM) is a rare but complex and potentially life-threatening autoimmune disease of childhood. Significant proportions of patients have residual weakness, muscle atrophy, joint contractures, and calcinosis. Recently, new clinical findings, such as lipodystrophy accompanied with increased fat deposition in certain areas, have been reported. So far, it is not known whether the redistribution of body fat may be the type of lipedema of lower extremity. We describe a 39-year-old woman who was diagnosed with JDM at the age of 7. Later she developed symmetrical lipodystrophy of upper extremities and symmetrical lipedema of lower extremities (making 2 and 58.3 % of total body fat mass, respectively), with multiple calcified nodules in the subcutaneous tissues. These nodules gradually increased in size despite therapy. Capillaroscopy findings showed scleroderma-like abnormalities. ANA and anti-U1RNP antibodies were positive. Similar cases with simultaneous occurrence of the lipedema of lower extremities, lipodystrophy of upper extremities, and severe calcinosis complicating JDM have not been published so far. We showed that the calcinosis and lipodystrophy were associated with short duration of active disease. Also, we display case that raises the question whether it is possible overlapping autoimmune diseases revealed during follow-up. © 2014, Springer-Verlag Berlin Heidelberg. - Some of the metrics are blocked by yourconsent settings
Publication Screen-film versus digital radiography of sacroiliac joints: Evaluation of image quality and dose to patients(2013) ;Jablanovic, Dragoslav (41461136000) ;Ciraj-Bjelac, Olivera (36106817400) ;Damjanov, Nemanja (8503557800) ;Seric, Srdjan (54880261200) ;Radak-Perovic, Marija (6507787195) ;Arandjic, Danijela (35108750400)Maksimovic, Ruzica (55921156500)The purpose of this paper is to evaluate the image quality and dose to patients in the radiography of sacroiliac joints and to perform a clinical comparative study of digital and conventional screen-film radiography. Routine radiography of sacroiliac joint was performed in 60 patients using digital and screen-film radiography. The visibility of five anatomical regions and the overall image quality were rated by experienced radiologists. Patient dose assessment in terms of entrance surface air kerma (ESAK) was performed. The digital system showed slightly improved visualisation of specificanatomical structures. Overall image quality was significantly better in the digital when compared with the screen-film imaging system. The average ESAK was 2.4 mGy in screen-film and 3.6 mGy in digital radiography. The digital radiography provided equal or better visibility of anatomical details and overall image quality, but on higher dose levels. Therefore, the practice on digital systems must be optimised. © The Author 2012. Published by Oxford University Press. All rights reserved. - Some of the metrics are blocked by yourconsent settings
Publication Screen-film versus digital radiography of sacroiliac joints: Evaluation of image quality and dose to patients(2013) ;Jablanovic, Dragoslav (41461136000) ;Ciraj-Bjelac, Olivera (36106817400) ;Damjanov, Nemanja (8503557800) ;Seric, Srdjan (54880261200) ;Radak-Perovic, Marija (6507787195) ;Arandjic, Danijela (35108750400)Maksimovic, Ruzica (55921156500)The purpose of this paper is to evaluate the image quality and dose to patients in the radiography of sacroiliac joints and to perform a clinical comparative study of digital and conventional screen-film radiography. Routine radiography of sacroiliac joint was performed in 60 patients using digital and screen-film radiography. The visibility of five anatomical regions and the overall image quality were rated by experienced radiologists. Patient dose assessment in terms of entrance surface air kerma (ESAK) was performed. The digital system showed slightly improved visualisation of specificanatomical structures. Overall image quality was significantly better in the digital when compared with the screen-film imaging system. The average ESAK was 2.4 mGy in screen-film and 3.6 mGy in digital radiography. The digital radiography provided equal or better visibility of anatomical details and overall image quality, but on higher dose levels. Therefore, the practice on digital systems must be optimised. © The Author 2012. Published by Oxford University Press. All rights reserved.
