    Publication
    Simultaneous blood temperature control and blood volume control reduces intradialytic symptoms
    (2011)
    Veljančić, Ljubiša (6505943776)
    ;
    Popović, Jovan (56715268600)
    ;
    Radović, Milan (57203260214)
    ;
    Ahrenholz, Peter (6603102920)
    ;
    Ries, Wolfgang (7005548390)
    ;
    Frenken, Leon (7004599530)
    ;
    Wojke, Ralf (9245790400)
    Purpose: Intra-dialytic morbid events (IME; e.g. hypotension, cramps, headaches) are frequent complications during hemodialysis (HD), known to be associated with ultrafiltration-induced hypovolemia and body temperature changes. Feedback control of blood volume adjusts the ultrafiltration rate in order to keep the blood volume above the patient's individual limit; feedback control of blood temperature maintains the mean arterial blood temperature at the individual pre-dialytic level. Each of these methods reduces the frequency of IME. Methods: In a randomized clinical trial the simultaneous application of both feedback controls was investigated for the first time. In 15 weeks, each patient went through 3 study phases: an observational screening phase, a standard phase (STD), and a blood temperature- and blood volume-control phase (CTL). Patients with at least 5 sessions with IME out of 15 sessions in the screening phase were eligible for the study and randomized either into sequence STD-CTL or CTL-STD. Results: 26 patients completed the study according to protocol, and 778 HD treatments were analyzed. The general treatment parameters were similar in both study phases: treatment duration (STD: 244 min, CTL: 243 min, NS), pre-dialytic weight (STD: 72.3 kg, CTL: 72.2 kg, NS), and weight loss due to ultrafiltration (STD: 3.26 kg, CTL: 3.15 kg, NS). The proportion of HD treatments with IME was 32.8% during STD and 18.0% during CTL (p=0.024). Conclusions: The frequency of HD sessions with IME was significantly reduced by 45% compared to standard HD in this randomized clinical trial by use of individualized HD treatments with simultaneous feedback control of blood volume and blood temperature. © 2011 Wichtig Editore.
  • Loading...
    Thumbnail Image
    Some of the metrics are blocked by your 
    consent settings
    Publication
    Simultaneous blood temperature control and blood volume control reduces intradialytic symptoms
    (2011)
    Veljančić, Ljubiša (6505943776)
    ;
    Popović, Jovan (56715268600)
    ;
    Radović, Milan (57203260214)
    ;
    Ahrenholz, Peter (6603102920)
    ;
    Ries, Wolfgang (7005548390)
    ;
    Frenken, Leon (7004599530)
    ;
    Wojke, Ralf (9245790400)
    Purpose: Intra-dialytic morbid events (IME; e.g. hypotension, cramps, headaches) are frequent complications during hemodialysis (HD), known to be associated with ultrafiltration-induced hypovolemia and body temperature changes. Feedback control of blood volume adjusts the ultrafiltration rate in order to keep the blood volume above the patient's individual limit; feedback control of blood temperature maintains the mean arterial blood temperature at the individual pre-dialytic level. Each of these methods reduces the frequency of IME. Methods: In a randomized clinical trial the simultaneous application of both feedback controls was investigated for the first time. In 15 weeks, each patient went through 3 study phases: an observational screening phase, a standard phase (STD), and a blood temperature- and blood volume-control phase (CTL). Patients with at least 5 sessions with IME out of 15 sessions in the screening phase were eligible for the study and randomized either into sequence STD-CTL or CTL-STD. Results: 26 patients completed the study according to protocol, and 778 HD treatments were analyzed. The general treatment parameters were similar in both study phases: treatment duration (STD: 244 min, CTL: 243 min, NS), pre-dialytic weight (STD: 72.3 kg, CTL: 72.2 kg, NS), and weight loss due to ultrafiltration (STD: 3.26 kg, CTL: 3.15 kg, NS). The proportion of HD treatments with IME was 32.8% during STD and 18.0% during CTL (p=0.024). Conclusions: The frequency of HD sessions with IME was significantly reduced by 45% compared to standard HD in this randomized clinical trial by use of individualized HD treatments with simultaneous feedback control of blood volume and blood temperature. © 2011 Wichtig Editore.
  • Loading...
    Thumbnail Image
    Some of the metrics are blocked by your 
    consent settings
    Publication
    Tissue plasminogen activator for dysfunctional tunneled vascular catheters for hemodialysis – Single center experience
    (2019)
    Todorov, Verica (58660982200)
    ;
    Janković, Aleksandar (55908877300)
    ;
    Đurić, Petar (37000455400)
    ;
    Bulatović, Ana (35736942600)
    ;
    Popović, Jovan (56715268600)
    ;
    Dimković, Nada (6603958094)
    Introduction/Objective Thrombosis of hemodialysis catheters is one of the major complications, which leads to catheter dysfunction. Although tissue plasminogen activator has been proven to be effective in reestablishing blood flow rate through dysfunctional catheters, clinical data in Serbia are missing. The objective of the study was to analyze tissue plasminogen activator efficacy in reestablishing blood flow rate and the influence on catheter survival. Methods The study included 53 tunneled catheters from 32 patients on hemodialysis. After catheter dysfunction was established, 580,000 units of tissue plasminogen activator was applied into each catheter lumen for about two hours before hemodialysis. The criteria for success was blood flow rate on the next hemodialysis – over 200 mL/minute was considered to be complete success, 180–200 mL/minute partial success, and under 180 mL/minute was considered a failure. Results Out of 53, 25 catheters (47%) had dysfunction with an incidence of 3.8/1,000 catheter days. Catheters placed in femoral veins, “after-first” catheters, catheters with infection, and catheters in older patients had higher risk for dysfunction. Multivariate logistic regression analysis confirmed that only older age was significantly related to catheter dysfunction. Of the total of 50 applications of tissue plasminogen activator, 35 (70%) were successful, seven procedures (14%) were partially successful and eight (16%) dysfunctional catheters failed to respond to therapy. Six-, 12-and 24-month survival was 87%, 81%, and 20%, respectively, for catheters without dysfunction, and 71%, 47.5%, and 12%, respectively, for catheters with dysfunction. Conclusion Tissue plasminogen activator dosing is noninvasive, efficient, and safe in reestablishing blood flow rate through dysfunctional catheters, thus prolonging catheters life and sparing patients from additional vascular procedures. © 2019, Serbia Medical Society. All rights reserved.