Browsing by Author "Janta, Iustina (55930777100)"
Now showing 1 - 3 of 3
- Results Per Page
- Sort Options
- Some of the metrics are blocked by yourconsent settings
Publication Performance of ultra-high-frequency ultrasound in the evaluation of skin involvement in systemic sclerosis: A preliminary report(2020) ;Naredo, Esperanza (6602827091) ;Pascau, Javier (6603062222) ;Damjanov, Nemanja (8503557800) ;Lepri, Gemma (55588064900) ;Gordaliza, Pedro M (56491169700) ;Janta, Iustina (55930777100) ;Ovalles-Bonilla, Juan Gabriel (55638537700) ;López-Longo, Francisco Javier (6603414978)Matucci-Cerinic, Marco (7005642558)High frequency ultrasound allows visualization of epidermis, dermis and hypodermis, precise measurement of skin thickness, as well as assessment of skin oedema, fibrosis and atrophy. The aim of this pilot cross-sectional observational study was to assess the performance and multiobserver variability of ultra-high-frequency (UHF) (50 MHz) ultrasound (US) in measuring skin thickness as well as the capacity of UHF-derived skin features to differentiate SSc patients from healthy controls. Methods: Twenty-one SSc patients (16 limited and five diffuse SSc) and six healthy controls were enrolled. All subjects underwent US evaluation by three experts at three anatomical sites (forearm, hand and finger). Dermal thickness was measured and two rectangular regions of interest, one in dermis and one in hypodermis, were established for texture feature analysis. Results: UHF-US allowed a precise identification and measurement of the thickness of the dermis. The dermal thickness in the finger was significantly higher in patients than in controls (P < 0.05), while in the forearm it was significantly lower in patients than in controls (P < 0.001). Interobserver variability for dermal thickness was good to excellent [forearm intraclass correlation coefficient (ICC) = 0.754; finger ICC = 0.699; hand ICC = 0.602]. Texture computed analysis of dermis and hypodermis was able to discriminate between SSc and healthy subjects (area under the curve >0.7). Conclusion: These preliminary data show that skin UHF-US allows a very detailed imaging of skin layers, a reliable measurement of dermal thickness, and a discriminative capacity between dermis and hypodermis texture features in SSc and healthy subjects. © 2019 The Author(s) 2019. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. - Some of the metrics are blocked by yourconsent settings
Publication The 2017 EULAR standardised procedures for ultrasound imaging in rheumatology(2017) ;Möller, Ingrid (7103192512) ;Janta, Iustina (55930777100) ;Backhaus, Marina (55357052600) ;Ohrndorf, Sarah (13205334300) ;Bong, David A. (6603031463) ;Martinoli, Carlo (7005449059) ;Filippucci, Emilio (6603881110) ;Sconfienza, Luca Maria (24448438200) ;Terslev, Lene (55949307900) ;Damjanov, Nemanja (8503557800) ;Hammer, Hilde Berner (7102733905) ;Sudol-Szopinska, Iwona (7003455916) ;Grassi, Walter (7005496865) ;Balint, Peter (7005110127) ;Bruyn, George A.W. (7006486448) ;D'Agostino, Maria Antonietta (26643055600) ;Hollander, Diana (57199077688) ;Siddle, Heidi J. (26650180700) ;Supp, Gabriela (55814504000) ;Schmidt, Wolfgang A. (7404056149) ;Iagnocco, Annamaria (6603972277) ;Koski, Juhani (7005081297) ;Kane, David (35787288500) ;Fodor, Daniela (24168513700) ;Bruns, Alessandra (57207968067) ;Mandl, Peter (56632095700) ;Kaeley, Gurjit S. (6507369276) ;Micu, Mihaela (36176375800) ;Ho, Carmen (7404652632) ;Vlad, Violeta (35724995700) ;Chávez-López, Mario (55930446200) ;Filippou, Georgios (57877288000) ;Cerón, Carmen Elena (56585652100) ;Nestorova, Rodina (24923396300) ;Quintero, Maritza (12757057400) ;Wakefield, Richard (7006151013) ;Carmona, Loreto (35263586300)Naredo, Esperanza (6602827091)Background In 2001, the European League Against Rheumatism developed and disseminated the first guidelines for musculoskeletal (MS) ultrasound (US) in rheumatology. Fifteen years later, the dramatic expansion of new data on MSUS in the literature coupled with technological developments in US imaging has necessitated an update of these guidelines. Objectives To update the existing MSUS guidelines in rheumatology as well as to extend their scope to other anatomic structures relevant for rheumatology. Methods The project consisted of the following steps: (1) a systematic literature review of MSUS evaluable structures; (2) a Delphi survey among rheumatologist and radiologist experts in MSUS to select MS and non-MS anatomic structures evaluable by US that are relevant to rheumatology, to select abnormalities evaluable by US and to prioritise these pathologies for rheumatology and (3) a nominal group technique to achieve consensus on the US scanning procedures and to produce an electronic illustrated manual (ie, App of these procedures). Results Structures from nine MS and non-MS areas (ie, shoulder, elbow, wrist and hand, hip, knee, ankle and foot, peripheral nerves, salivary glands and vessels) were selected for MSUS in rheumatic and musculoskeletal diseases (RMD) and their detailed scanning procedures (ie, patient position, probe placement, scanning method and bony/other landmarks) were used to produce the App. In addition, US evaluable abnormalities present in RMD for each anatomic structure and their relevance for rheumatology were agreed on by the MSUS experts. Conclusions This task force has produced a consensus-based comprehensive and practical framework on standardised procedures for MSUS imaging in rheumatology. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted. - Some of the metrics are blocked by yourconsent settings
Publication The 2017 EULAR standardised procedures for ultrasound imaging in rheumatology(2017) ;Möller, Ingrid (7103192512) ;Janta, Iustina (55930777100) ;Backhaus, Marina (55357052600) ;Ohrndorf, Sarah (13205334300) ;Bong, David A. (6603031463) ;Martinoli, Carlo (7005449059) ;Filippucci, Emilio (6603881110) ;Sconfienza, Luca Maria (24448438200) ;Terslev, Lene (55949307900) ;Damjanov, Nemanja (8503557800) ;Hammer, Hilde Berner (7102733905) ;Sudol-Szopinska, Iwona (7003455916) ;Grassi, Walter (7005496865) ;Balint, Peter (7005110127) ;Bruyn, George A.W. (7006486448) ;D'Agostino, Maria Antonietta (26643055600) ;Hollander, Diana (57199077688) ;Siddle, Heidi J. (26650180700) ;Supp, Gabriela (55814504000) ;Schmidt, Wolfgang A. (7404056149) ;Iagnocco, Annamaria (6603972277) ;Koski, Juhani (7005081297) ;Kane, David (35787288500) ;Fodor, Daniela (24168513700) ;Bruns, Alessandra (57207968067) ;Mandl, Peter (56632095700) ;Kaeley, Gurjit S. (6507369276) ;Micu, Mihaela (36176375800) ;Ho, Carmen (7404652632) ;Vlad, Violeta (35724995700) ;Chávez-López, Mario (55930446200) ;Filippou, Georgios (57877288000) ;Cerón, Carmen Elena (56585652100) ;Nestorova, Rodina (24923396300) ;Quintero, Maritza (12757057400) ;Wakefield, Richard (7006151013) ;Carmona, Loreto (35263586300)Naredo, Esperanza (6602827091)Background In 2001, the European League Against Rheumatism developed and disseminated the first guidelines for musculoskeletal (MS) ultrasound (US) in rheumatology. Fifteen years later, the dramatic expansion of new data on MSUS in the literature coupled with technological developments in US imaging has necessitated an update of these guidelines. Objectives To update the existing MSUS guidelines in rheumatology as well as to extend their scope to other anatomic structures relevant for rheumatology. Methods The project consisted of the following steps: (1) a systematic literature review of MSUS evaluable structures; (2) a Delphi survey among rheumatologist and radiologist experts in MSUS to select MS and non-MS anatomic structures evaluable by US that are relevant to rheumatology, to select abnormalities evaluable by US and to prioritise these pathologies for rheumatology and (3) a nominal group technique to achieve consensus on the US scanning procedures and to produce an electronic illustrated manual (ie, App of these procedures). Results Structures from nine MS and non-MS areas (ie, shoulder, elbow, wrist and hand, hip, knee, ankle and foot, peripheral nerves, salivary glands and vessels) were selected for MSUS in rheumatic and musculoskeletal diseases (RMD) and their detailed scanning procedures (ie, patient position, probe placement, scanning method and bony/other landmarks) were used to produce the App. In addition, US evaluable abnormalities present in RMD for each anatomic structure and their relevance for rheumatology were agreed on by the MSUS experts. Conclusions This task force has produced a consensus-based comprehensive and practical framework on standardised procedures for MSUS imaging in rheumatology. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
