Browsing by Author "Jankovic, Milica M. (36611860300)"
Now showing 1 - 2 of 2
- Results Per Page
- Sort Options
- Some of the metrics are blocked by yourconsent settings
Publication Renal output efficiency and normalized residual activity examined by technetium-99m-DTPA renography have by far greater specificity to diagnose obstructive disease as compared to other conventional parameters of the renogram. First such study of output efficiency(2018) ;Beatovic, Slobodanka Lj (6507312377) ;Radulovic, Marija (56789775400) ;Jankovic, Milica M. (36611860300) ;Artiko, Vera M. (55887737000) ;Ajdinovic, Boris (24167888800)Sobic-Saranovic, Dragana P. (57202567582)Objective: The aim of this study was to assess the diagnostic ability of renal output efficiency (OE), normalized residual activity (NORA) and conventional interpretation of the diethylene triamine pentaacetic acid (99mTc-DTPA) diuretic renogram (CIR) in diagnosing urine flow obstruction. Subjects and Methods: Group A consisted of 73 obstructed kidneys and Group B of 80 kidneys with dilated upper urinary tract. Forty eight kidneys were examined as the control Group C. A 40min acquisition with 240 of 10sec images was applied. Furosemide was administered after 20min (F+20). Post-void image was acquired at 50min. Output effici-ency was calculated at 20min (OE20) and 20min after furosemide test (OE40) and NORA at 20min (NORA20) and on the post-micturition acquisition (NORAPM). Results: Both the above parameters (OE40 and NORAPM) had high sensitivity (92% and 97%), specificity (99% for both) and accuracy (95% and 98%) in differenti-ating between obstructed and dilated unobstructed kidneys. The test of NORAPM correctly reclassified 40 out of 41 indeterminate or false positive results of the conventional interpretations of renograms (CIR) as obstructed (12 cases) or dilated (28 cases). Cut-off values for obstruction were <80% and 0.23 for OE40 and NORAPM, respectively. Compared to CIR, both parameters showed better specificity, especially NORAPM . Conclusion: Factors of OE40 and especially NORAPM of the renogram by 99mTc-DTPA were able to diagnose urine outflow obstruction better than CIR. Specifically, these factors well differentiated obstruction from urinary tract dilatation. © 2018 P.Ziti and Co. All rights reserved. - Some of the metrics are blocked by yourconsent settings
Publication Validation of IAEA software package for the analysis of scintigraphic renal dynamic studies: Parameters of renal transit in children with renal pelvic dilatation(2014) ;Beatovic, Slobodanka Lj. (6507312377) ;Sobic-Saranovic, Dragana P. (57202567582) ;Jaksic, Emilija D. (6507797044) ;Jankovic, Milica M. (36611860300) ;Marinkovic, Jelena (7004611210)Obradovic, Vladimir B. (7003389726)PURPOSE: The objectives of the study were to use the International Atomic Energy Agency (IAEA) software package for the analysis of scintigraphic renal dynamic studies to obtain values of curve parameters and excretory parameters in children with hydronephrosis and to validate the reliability of these numerical outputs by comparing with values established by consensus reports. PATIENTS AND METHODS: Fifty children with hydronephrosis (median age, 16 months; 30 boys, 20 girls; 99 kidneys) underwent Tc-MAG3 diuresis renography. Studies were analyzed by 2 observers, and according to the assessment of images, renograms, and differential function, kidneys were classified as normal (42, kidneys contralateral to hydronephrotic kidney), hypotonic unobstructed (49), and obstructed (8). The IAEA software was applied to each renogram. The parameters analyzed were as follows: normalized residual activity at 20 minutes (NORA 20) and on postmicturition (PM) acquisition, output efficiency at 20 minute (OE 20), PM to maximum renal count ratio (PM/max), and mean transit time (MTT). RESULTS: Mean values for normal, hypotonic unobstructed, and obstructed kidneys were as follows: NORA 20: 0.25, 0.57, and 2.16; OE 20 (%): 94.5, 87, and 57; normalized residual activity on PM acquisition: 0.02, 0.03, and 0.27; PM/max: 0.01, 0.02, and 0.13; and MTT (minutes): 1.9, 3.5, and 8.9, respectively. Difference between obstruction/dilatation and normal/dilatation was significant (P < 0.0001), as well as the correlation between NORA 20/OE 20 (R =-0.982). Cutoff values to predict obstruction were as follows: NORA 20, 1.6; OE 20, 73%; NORA PM, 0.11; PM/max, 0.06; and MTT, 8.23 minutes. CONCLUSIONS: The IAEA software package gives reliable values of numerical parameters of renal excretion. The use of the software improves diagnostic accuracy of diuresis renography in children. © 2014 Lippincott Williams and Wilkins.