Repository logo
  • English
  • Srpski (lat)
  • Српски
Log In
Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "Jankov, Mirko R. (13003630000)"

Filter results by typing the first few letters
Now showing 1 - 2 of 2
  • Results Per Page
  • Sort Options
  • Loading...
    Thumbnail Image
    Some of the metrics are blocked by your 
    consent settings
    Publication
    Clinical impact of nanophotonic blue-light filtering spectacles based on fullerene C60 and polymethyl methacrylate (PMMA)
    (2021)
    Jankov, Mirko R. (13003630000)
    ;
    Jakšiæ, Vesna (57223885117)
    ;
    Koruga, Djuro (7004245135)
    Background/Aim. Blue light might be harmful to the reti-na. The nano-material based on fullerene C60 and polyme-thyl methacrylate (PMMA) transforms the light into harmo-nized light and absorbs violet, blue, and ultraviolet (UV) wavelength. The aim of the study was to evaluate the sub-jective and objective impact of the spectacles on daily activi-ties. Methods. Twenty-five healthy participants were sub-mitted to contrast sensitivity (CS) and visual field (VF) test-ing and a questionnaire about the influence of spectacles on daily activities: two spectacles with different concentrations of fullerene C60 vs. two commercially available blue-blocking spectacles. Results. There was no statistical differ-ence in CS (p = 0.83), in VF parameters: mean deviation (MD) (p = 0.36), pattern standard deviation (PSD) (p = 0.25), number of relative scotomas (p = 0.31), while the number of absolute scotomas showed a statistically signifi-cant decrease (p < 0.05). Spectacles B (with a lower concen-tration of fullerene - 0.025%) had the best overall comfort mean score (p < 0.00001): four-fifths of participants per-formed better only during the day, while two-thirds per-formed better both during the day and night. Spectacles B were also superior in overall satisfaction regarding all com-bined daily activities (4.04 ± 1.1) (p = 0.0008). Conclusion. Blue-blocking filters with fullerene C60 increase the overall comfort of daily tasks during and after their use. These fil-ters might be an effective mechanism that can protect us from ocular pathologies while providing better comfort in daily activities. © 2021 Inst. Sci. inf., Univ. Defence in Belgrade. All rights reserved.
  • Loading...
    Thumbnail Image
    Some of the metrics are blocked by your 
    consent settings
    Publication
    Corneal Cross-linking for the treatment of keratoconus: Preliminary; [Ultra B2 - Promoção de ligações covalentes do colágeno corneal (Corneal cross-linking) no tratamento de ceratocone: Resultados preliminares]
    (2008)
    Jankov, Mirko R. (13003630000)
    ;
    Hafezi, Farhad (57203017009)
    ;
    Beko, Maja (26667512800)
    ;
    Ignjatovic, Zora (26667721500)
    ;
    Djurovic, Branislav (36905355700)
    ;
    Markovic, Vujica (56233157100)
    ;
    Schor, Paulo (6602119864)
    Purpose: To present early visual and keratometric results for corneal cross-linking with riboflavin and UV irradiation in patients with progressive keratoconus. Methods: Twentyfive eyes of twenty patients (15 males and 5 females) with a progressive keratoconus in the previous 6 months were followed. Unaided visual acuity (UVA), best spectacle corrected visual acuity (BSCVA), spherical equivalent (SEQ), manifest cylinder, and maximal corneal curvature (max K) values were followed at 1, 3 and 6 months. All patients were submitted to corneal cross-linking using riboflavin (vitamin B2) as the photosensitizer and ultraviolet light (UV, wavelength 370 nm). Epithelium was removed with 20% alcohol, cornea was soaked with vitamin B2 for 15 min, and then irradiated with UV light for 30 min, after which a bandage contact lens (BCL) was placed. Results: UVA increased after one month (from 0.15 ± 0.15 to 0.23 ± 0.20), and went on increasing at 3 and 6 months, reaching statistical significance (p=0.025 e p=0.037, respectively). BSCVA increased from 0.41 ± 0.27 to 0.49 ± 0.29 at month six, without reaching statistical signifi-cance at any time point. Progression of keratoconus stopped in all patients, in contrast with progression in all of them in the six-month period prior to the surgery. Max K decreased by more than 2 D (from 53.02 ± 8.42 to 50.88 ± 6.05 D), SEQ less that 1 D (from -3.27 ± 4.08 to -2.68 ± 3.02 D), while refractive cylinder decreased less than 0.5 D (from -2.29 ± 1.77 to -1.86 ± 0.92 D), without reaching a statistically significant difference. None of the eyes lost any line of BSCVA, 12 maintained the preoperative BSCVA, 7 gained one line, 5 gained two lines, and 1 patient gained three lines of BSCVA. Conclusions: Corneal cross-linking with riboflavin and UV light seems to be a safe (no loss of BSCVA) and effective (anatomical and optical properties maintained) procedure, which has shown to stop the progression of the keratoconus: a reduction, although not statistically significant, of the corneal curvature, spherical equivalent and refractive cylinder took place in patients where previous progression of keratoconus had been described.

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Privacy policy
  • End User Agreement
  • Send Feedback