    Computerized rhinomanometry: a study of total nasal resistance normal values.
    (2009)
    Janosević, L. (6603730103)
    ;
    Dotlić, J. (6504769174)
    ;
    Janosević, S. (7003636278)
    ;
    Dudvarski, Z. (6504165244)
    ;
    Milovanović, A. (57213394853)
    ;
    Pendjer, I. (6506856527)
    Computerized rhinomanometry with the practical software programmes is used widely as a research tool to evaluate objectively nasal air flow and resistance parameters, while the increase of its clinical application may be facilitated by further standardization of the method. The aim of the study was to determine the total nasal resistance normal values in healthy adult population using a method of computerized rhinomanometry. A randomized sample of 108 white healthy adults (216 nasal cavities), both sexs with a mean age of 32 (20-45) years comprised the test group. Nasal patency was measured by active anterior rhinomanometry in non-decongested mucosa ("at rest") during 10 repetitive measurements at inspiratory and expiratory reference pressure of 150 Pa. Nasal resistance was measured and calculated according to the recommendations of the Committee on objective assessment of the nasal airway, International Rhinologic Society. The mean total nasal resistance in the sample was found to be 0.179 Pa/cm3/s with the confidant interval from 0,167 to 0,191 Pa/cm3/s at the probability level of 95%. Total nasal resistance was very significantly influenced by sex (t = -4.614), height (F=11.625) and weight (F=11.529) of the examinees. This paper provides additional information on total nasal resistance normal values in healthy adult population important for computirezed rhinomanometry normative parameters standardization.
  • Loading...
    Thumbnail Image
    Some of the metrics are blocked by your 
    consent settings
    Publication
    Fetal hydrops and middle cerebral artery Doppler in prediction degree of fetal anemia and the best timing for therapy
    (2017)
    Babović, I. (14828590600)
    ;
    Plešinac, S. (55920049900)
    ;
    Sparić, R. (23487159800)
    ;
    Dotlić, J. (6504769174)
    ;
    Pilić, I. (13612571200)
    ;
    Nejković, L. (55566568600)
    ;
    Plećaš, D. (6603715745)
    Purpose: To determine the role of fetal multiples of the median of middle cerebral artery peak systolic velocity (MoM MCA-PSV), in predicting the degree of fetal anemia for determination of the best timing for the second intrauterine intravascular transfusion (IUIVT) in hydropic fetuses with Rh alloimmunization. Materials and Methods: Prospective study of 30 monofetal pregnancies with maternal Rh D alloimmunization and hydrops fetalis, from 2005 to 2012 that underwent first and second IUIVT were assessed. Results: Thirty IUIVT were performed at 26.9 weeks (standard deviation, SD 4.3). Mean interval to the second procedure was 11.23 (SD 6.21) days and average hematocrit decline rate was 1.45%/day. The study did not demonstrated statistical significance between MCA-MoM-3 before the second IUIVT, and the mean decline rate in fetal hematocrit levels (expressed in percentage/day) r = 0.220; p = 0.242, and between MCA-MoM-3 and the time interval between both procedures (T) r = -0.157; p = 0.408. Conclusion: The measurements fetal MoMMCA before every IUIVT cannot be useful as predictor for the best timing for the next IUIVT, but it can be useful in predicting severity of fetal anemia.