Browsing by Author "Djukic, Tijana (55625822200)"
Now showing 1 - 4 of 4
- Results Per Page
- Sort Options
- Some of the metrics are blocked by yourconsent settings
Publication Modeling of liver metastatic disease with applied drug therapy(2014) ;Filipovic, Nenad (35749660900) ;Djukic, Tijana (55625822200) ;Saveljic, Igor (55565816700) ;Milenkovic, Petar (35574505300) ;Jovicic, Gordana (24465471500)Djuric, Marija (12243542300)Colorectal carcinoma is acknowledged as the second leading cause of total cancer-related death in the European Region. The majority of deaths related to colorectal carcinoma are connected with liver metastatic disease. Approximately, in 25% of all patients, liver metastatic disease is diagnosed at the same time as the primary diagnosis, while up to a quarter of others would develop liver metastases in the course of the illness. In this study, we developed reaction-diffusion model and analyzed the effect of drug therapy on liver metastatic disease for a specific patient. Tumor volumes in specific time points were obtained using CT scan images. The nonlinear function for cell proliferation rate as well as data about clinically applied drug therapy was included in the model. Fitting procedure was used for parameter estimation. Good agreement of numerical and experimental results shows the feasibility and efficacy of the proposed system. © 2014 Elsevier Ireland Ltd. - Some of the metrics are blocked by yourconsent settings
Publication Modeling of liver metastatic disease with applied drug therapy(2014) ;Filipovic, Nenad (35749660900) ;Djukic, Tijana (55625822200) ;Saveljic, Igor (55565816700) ;Milenkovic, Petar (35574505300) ;Jovicic, Gordana (24465471500)Djuric, Marija (12243542300)Colorectal carcinoma is acknowledged as the second leading cause of total cancer-related death in the European Region. The majority of deaths related to colorectal carcinoma are connected with liver metastatic disease. Approximately, in 25% of all patients, liver metastatic disease is diagnosed at the same time as the primary diagnosis, while up to a quarter of others would develop liver metastases in the course of the illness. In this study, we developed reaction-diffusion model and analyzed the effect of drug therapy on liver metastatic disease for a specific patient. Tumor volumes in specific time points were obtained using CT scan images. The nonlinear function for cell proliferation rate as well as data about clinically applied drug therapy was included in the model. Fitting procedure was used for parameter estimation. Good agreement of numerical and experimental results shows the feasibility and efficacy of the proposed system. © 2014 Elsevier Ireland Ltd. - Some of the metrics are blocked by yourconsent settings
Publication Software for optimized virtual stenting of patient-specific coronary arteries reconstructed from angiography images(2024) ;Djukic, Tijana (55625822200) ;Tomasevic, Smiljana (57430908700) ;Saveljic, Igor (55565816700) ;Vukicevic, Arso (55568836700) ;Stankovic, Goran (59150945500)Filipovic, Nenad (35749660900)Detection of clinically relevant stenosis within coronary arteries as well as planning of treatment (stent implantation) are important topics in clinical cardiology. In this study a thorough methodology for virtual stenting assistance is proposed, that includes the 3D reconstruction of a patient-specific coronary artery from X-ray angiography images, hemodynamic simulations of blood flow, computation of a fractional flow reserve (FFR) equivalent, virtual stenting procedure and an optimization of the virtual stenting, by considering not only the value of computed FFR, but also the low and high WSS regions and the state of arterial wall after stenting. The evaluation of the proposed methodology is performed in two ways: the calculated values of FFR are compared with clinically measured values; and the results obtained for automated optimized virtual stenting are compared with virtual stenting performed manually by an expert clinician for the whole considered dataset. The agreement of the results in almost all cases demonstrates the accuracy of the proposed approach, and the small discrepancies only show the capabilities and benefits this approach can offer. The automated optimized virtual stenting technique can provide information about the most optimal stent position that ensures the maximum achievable FFR, while also considering the distribution of WSS and the state of arterial wall. The proposed methodology and developed software can therefore be used as a noninvasive method for planning of optimal patient-specific treatment strategies before invasive procedures and thus help to improve the clinical outcome of interventions and provide better treatment planning adapted to the particular patient. © 2024 Elsevier Ltd - Some of the metrics are blocked by yourconsent settings
Publication Software for optimized virtual stenting of patient-specific coronary arteries reconstructed from angiography images(2024) ;Djukic, Tijana (55625822200) ;Tomasevic, Smiljana (57430908700) ;Saveljic, Igor (55565816700) ;Vukicevic, Arso (55568836700) ;Stankovic, Goran (59150945500)Filipovic, Nenad (35749660900)Detection of clinically relevant stenosis within coronary arteries as well as planning of treatment (stent implantation) are important topics in clinical cardiology. In this study a thorough methodology for virtual stenting assistance is proposed, that includes the 3D reconstruction of a patient-specific coronary artery from X-ray angiography images, hemodynamic simulations of blood flow, computation of a fractional flow reserve (FFR) equivalent, virtual stenting procedure and an optimization of the virtual stenting, by considering not only the value of computed FFR, but also the low and high WSS regions and the state of arterial wall after stenting. The evaluation of the proposed methodology is performed in two ways: the calculated values of FFR are compared with clinically measured values; and the results obtained for automated optimized virtual stenting are compared with virtual stenting performed manually by an expert clinician for the whole considered dataset. The agreement of the results in almost all cases demonstrates the accuracy of the proposed approach, and the small discrepancies only show the capabilities and benefits this approach can offer. The automated optimized virtual stenting technique can provide information about the most optimal stent position that ensures the maximum achievable FFR, while also considering the distribution of WSS and the state of arterial wall. The proposed methodology and developed software can therefore be used as a noninvasive method for planning of optimal patient-specific treatment strategies before invasive procedures and thus help to improve the clinical outcome of interventions and provide better treatment planning adapted to the particular patient. © 2024 Elsevier Ltd
