Browsing by Author "Damnjanovic-Pazin, Barbara (35490278400)"
Now showing 1 - 2 of 2
- Results Per Page
- Sort Options
- Some of the metrics are blocked by yourconsent settings
Publication Screening performance of congenital heart defects in first trimester using simple cardiac scan, nuchal translucency, abnormal ductus venosus blood flow and tricuspid regurgitation(2019) ;Karadzov Orlic, Natasa (41561546900) ;Egic, Amira (12773957600) ;Damnjanovic-Pazin, Barbara (35490278400) ;Lukic, Relja (6603430390) ;Joksic, Ivana (14054233100)Mikovic, Zeljko (7801694296)Objective: The objective of this study was to analyze if the addition of simple cardiac scan in cases with increased nuchal translucency (NT) and/or abnormal ductus venosus (DV) blood flow, and/or tricuspid regurgitation (TCR) can improve detection of congenital heart defects (CHD) in chromosomally normal fetuses without non-cardiac defects at 11-13 + 6 gestational weeks in a population of singleton pregnancies. Methods: During the 10 years period, all singleton pregnancies at 11-13 + 6 weeks were routinely scanned for NT, DV blood flow and TCR assessment and, if a single of these parameters was abnormal, simple cardiac scan with 2D gray scale and color and/or directional power Doppler in 4-chamber (4-CV) and 3 vessel and trachea views (3VTV) was performed. Results: The sensitivity and specificity of NT ≥ 95th + DV R/A a-wave + TCR in detecting CHD were 77% and 97%, respectively, and of simple cardiac scan, 67% and 98%, respectively. Area under the curve of receiver operating characteristic curve of NT ≥ 95th + DV R/A a-wave + TCR was 0.838, and of NT ≥ 95th + DV R/A a-wave + TCR + simple cardiac scan was 0.915. Conclusions: In chromosomally normal fetuses without non-cardiac anomalies, addition of simple cardiac scan to the combined first trimester screening parameters improves detection of major CHD during first trimester. © 2019 Wiley Periodicals, Inc. - Some of the metrics are blocked by yourconsent settings
Publication Screening performances of abnormal first-trimester ductus venosus blood flow and increased nuchal translucency thickness in detection of major heart defects(2015) ;Karadzov-Orlic, Natasa (41561546900) ;Egic, Amira (12773957600) ;Filimonovic, Dejan (23990830300) ;Damnjanovic-Pazin, Barbara (35490278400) ;Milovanovic, Zagorka (24829789900) ;Lukic, Relja (6603430390) ;Mandic, Vesna (23991079100) ;Joksic, Ivana (14054233100) ;Vukomanovic, Vladimir (55270425900) ;Kosutic, Jovan (55928740700) ;Djuricic, Slavisa (6603108728)Mikovic, Zeljko (7801694296)Objective: The aim of this study was to evaluate the screening performances of abnormal ductus venosus (DV) blood flow for the detection of heart defects in chromosomally normal fetuses with increased nuchal translucency (NT) thickness at 11-13+6weeks' gestational in a population of singleton pregnancies. Methods: During an 8-year period, all singleton pregnancies from 11+0 to 13+6weeks were scanned for NT and DV blood flow assessment. Two groups of cases with abnormal NT were evaluated: NT≥95th and NT≥99th centile. DV waveforms were considered to be abnormal if the a-wave was reversed or absent (R/A). Results: Addition of DV R/A a-wave to either NT≥95th or NT≥99th percentile increased specificity (p<0.001 and p<0.001, respectively), but not screening performances in detection of major heart defects (p=0.73 and p=0.91, respectively). Combination of DV R/A a-wave with NT≥95th or NT≥99th centile correlated with right heart defects (p=0.024 and p=0.013, respectively). Conclusions: In chromosomally normal fetuses, addition of abnormal DV a-wave to increased NT does not improve screening performances of NT in detection of major hearts defects in first trimester. However, there is correlation of such parameter with right heart defects and AV septal defects. What's already known about this topic? Measurement of NT thickness in first trimester is a standard clinical practice of prenatal screening for heart defects. There are conflicting results whether the addition of qualitative assessment of ductus venosus flow improves screening performances of increased NT for heart defects. What does this study add? Addition of reduced or absent DV a-wave to increased NT improves its specificity for detection of major heart defects during the first trimester. Reduced or absent a-wave of DV flow in combination with increased NT correlates with increased risk of right heart defects and AV septal defects. © 2015 John Wiley & Sons, Ltd.