    Eye lens dosimetry in interventional cardiology: Results of staff dose measurements and link to patient dose levels
    (2013)
    Antic, V. (55647858000)
    ;
    Ciraj-Bjelac, O. (36106817400)
    ;
    Rehani, M. (7003893393)
    ;
    Aleksandric, S. (35274271700)
    ;
    Arandjic, D. (35108750400)
    ;
    Ostojic, M. (34572650500)
    Workers involved in interventional cardiology procedures receive high eye lens dose if protection is not used. Currently, there is no suitable method for routine use for the measurement of eye dose. Since most angiography machines are equipped with suitable patient dosemeters, deriving factors linking staff eye doses to the patient doses can be helpful. In this study the patient kerma-area product, cumulative dose at an interventional reference point and eye dose in termsof Hp(3) of the cardiologists, nurses and radiographers for interventional cardiology procedures have been measured. Correlations between the patient dose and the staff eye dose were obtained. The mean eye dose was 121 mSv for the first operator, 33 mSv for the second operator/nurse and 12 mSv for radiographer. Normalised eye lens doses per unit kerma-area product were 0.94 mSv Gy-1 cm-2 for the first operator, 0.33 mSv Gy-1 cm-2 for the second operator/nurse and 0.16 mSv Gy-1 cm-2 for radiographers. Statistical analysis indicated that there is a weak but significant (p < 0.01) correlation between the eye dose and the kerma-area product for all three staff categories. These values are based on a local practiceand may provide useful reference for other studies for validation and for wider utilisation in assessing the eye dose using patient dose values. ©The Author 2012. Published by Oxford University Press.
  • Loading...
    Thumbnail Image
    Some of the metrics are blocked by your 
    consent settings
    Publication
    Eye lens dosimetry in interventional cardiology: Results of staff dose measurements and link to patient dose levels
    (2013)
    Antic, V. (55647858000)
    ;
    Ciraj-Bjelac, O. (36106817400)
    ;
    Rehani, M. (7003893393)
    ;
    Aleksandric, S. (35274271700)
    ;
    Arandjic, D. (35108750400)
    ;
    Ostojic, M. (34572650500)
    Workers involved in interventional cardiology procedures receive high eye lens dose if protection is not used. Currently, there is no suitable method for routine use for the measurement of eye dose. Since most angiography machines are equipped with suitable patient dosemeters, deriving factors linking staff eye doses to the patient doses can be helpful. In this study the patient kerma-area product, cumulative dose at an interventional reference point and eye dose in termsof Hp(3) of the cardiologists, nurses and radiographers for interventional cardiology procedures have been measured. Correlations between the patient dose and the staff eye dose were obtained. The mean eye dose was 121 mSv for the first operator, 33 mSv for the second operator/nurse and 12 mSv for radiographer. Normalised eye lens doses per unit kerma-area product were 0.94 mSv Gy-1 cm-2 for the first operator, 0.33 mSv Gy-1 cm-2 for the second operator/nurse and 0.16 mSv Gy-1 cm-2 for radiographers. Statistical analysis indicated that there is a weak but significant (p < 0.01) correlation between the eye dose and the kerma-area product for all three staff categories. These values are based on a local practiceand may provide useful reference for other studies for validation and for wider utilisation in assessing the eye dose using patient dose values. ©The Author 2012. Published by Oxford University Press.

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Privacy policy
  • End User Agreement
  • Send Feedback