Repository logo
  • English
  • Srpski (lat)
  • Српски
Log In
Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "Behar-Cohen, Francine (7005808435)"

Filter results by typing the first few letters
Now showing 1 - 1 of 1
  • Results Per Page
  • Sort Options
  • Loading...
    Thumbnail Image
    Some of the metrics are blocked by your 
    consent settings
    Publication
    CHANGES IN VISUAL ACUITY AND PHOTORECEPTOR DENSITY USING ADAPTIVE OPTICS AFTER RETINAL DETACHMENT REPAIR
    (2020)
    Potic, Jelena (55293803000)
    ;
    Bergin, Ciara (24178646600)
    ;
    Giacuzzo, Clarice (57200127516)
    ;
    Daruich, Alejandra (55362251100)
    ;
    Pournaras, Jean-Antoine (8506622000)
    ;
    Kowalczuk, Laura (26430999000)
    ;
    Behar-Cohen, Francine (7005808435)
    ;
    Konstantinidis, Lazaros (14039078900)
    ;
    Wolfensberger, Thomas J. (7004757176)
    Purpose:To quantify changes in photoreceptor density using adaptive optics fundus camera in patients after retinal detachment (RD) and to correlate them with macular involvement and best-corrected visual acuity.Methods:At 1 and 3 months (M1 and M3) after vitrectomy, 194 patients underwent adaptive optics imagery in both eyes, at 5 locations, that we matched between time points using anatomical landmarks. Twenty-two patients (10 fovea-OFF [OFF] and 12 fovea-ON [ON]) had matched and analyzable adaptive optics images. We used analysis of variance for repeated measures.Results:Best-corrected visual acuity (logarithm of the minimum angle of resolution and Snellen equivalent [SE]) was significantly different between OFF and ON RDs at baseline: 2.0 (2.3-0.95) (SE: 20/2000) versus 0 (0.1-0) (SE: 20/20); at M1: 0.35 (0.5-0.1) (SE: 20/40) versus 0.05 (0-0.1) (SE: 20/25); and at M3: 0.25 (0.3-0.1) (SE: 20/32) versus 0 (0-0) (SE: 20/20). We observed that cone density was stable in fellow eyes between M1 and M3 (P = 0.67); decreased in treated eyes than in fellow eyes (P < 0.05); and increased postoperatively in the ON group (P = 0.02) but not in the OFF group (P = 0.97). Visual acuity and RD type were independently correlated with cone density (P = 0.004, P = 0.000).Conclusion:Postoperative cone density was reduced in OFF RD, but also in the ON group, although the drop recovered during the 3-month follow-up. Cone density was significantly correlated with both visual acuity and type of RD at both time points. Copyright © by Ophthalmic Communications Society, Inc.

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Privacy policy
  • End User Agreement
  • Send Feedback