Browsing by Author "Beatović, Slobodanka Lj. (6507312377)"
Now showing 1 - 4 of 4
- Results Per Page
- Sort Options
- Some of the metrics are blocked by yourconsent settings
Publication Diagnostic performances and clinical usefulness of comprehensive non-commercial software for renogram analysis – values of renal output efficiency and normalized residual activity in suspected kidney outflow obstruction(2021) ;Beatović, Slobodanka Lj. (6507312377) ;Radulović, Marija (56789775400) ;Durutović, Otaš R. (6506011266) ;Veljković, Miloš M. (57211281286) ;Šaponjski, Jelena M. (57207943674) ;Artiko, Vera M. (55887737000)Šobić-šaranović, Dragana P. (57202567582)Introduction/Objective Nuclear Medicine Section of IAEA has developed the software for dynamic renal scintigraphy, which allows calculation of advanced parameters of drainage: renal output efficiency (OE) and normalized residual activity (NORA). The aim of this study was to validate IAEA software by comparing results of parameters of renal drainage in normal subjects against their established reference values and to assess diagnostic accuracy of OE and NORA in distinguishing between obstruction/unobstruction. Methods Fifty-five patients with suspected obstruction and 36 kidney donors were investigated. Group A consisted of 24 obstructed kidneys, Group B of 37 kidneys with dilated urinary tract, and Group C of 72 normal kidneys. Forty-minute acquisition was applied. Furosemide was administered after 20 minutes. Post-micturition image was acquired at 50 minutes. The analyzed parameters were as follows: OE at 20 minutes (OE20) and at the end of the furosemide test (OE40), NORA at 20 minutes (NORA20) and after micturition (NORAPM). One-way ANOVA was used for evaluating the differences between the groups. Ability of OE40 and NORAPM to distinguish between obstruction/unobstruction was determined by ROC curve analysis. The sensitivity, specificity, area under the curve, and cut-off values were analyzed. Results Excellent agreement of our results with established OE and NORA values was found. The difference between the groups was significant for OE20, OE40, NORA20,and NORA (p < 0.001). Cut-off values PM for obstruction were 82% and 0.11 for OE40 and NORAPM, respectively. Conclusion IAEA software gives reliable analysis of diuretic renography and helps to better diagnose obstruction. IAEA should be encouraged to produce final version of the software and to release it online. © 2021, Serbia Medical Society. All rights reserved. - Some of the metrics are blocked by yourconsent settings
Publication GammaKey system for improved diagnostics with gamma cameras(2014) ;Janković, Milica M. (36611860300) ;Pijetlović, Boris (56167841500) ;Marković, Ana Koljević (57198206230) ;Todorović-Tirnanić, Mila V. (12772684600) ;Beatović, Slobodanka Lj. (6507312377) ;Antić, Vojislav (55647858000) ;Odalović, Strahinja (57218390032) ;Sekulić, Stevan (56167436300) ;Jorgovanović, Nikola (24461567100)Popović, Dejan B. (7201969165)We designed the GammaKey system for the acquisition, storage and analysis of images from semi-analogue gamma scintillation cameras (GSCs). The GammaKey system, operating on a standard PC, replicates the functionality of earlier dedicated computer systems, allows the exchange of data in the DICOM format and has an open architecture enabling the development of new diagnostic techniques. The main purpose of the GammaKey is to enable the continued use of old GSCs which have functional scintillation crystals, but also to permit data exchange with new digital GSCs. The GammaKey has been technically validated by standards established by the National Electrical Manufacturers Association. The GammaKey has been used for seven years in two leading centres for nuclear medicine in Serbia (the Clinical Center of Serbia, Belgrade, and the Clinical Center of Vojvodina, Novi Sad) in approximately 30,000 patients. Clinical application proves that the GammaKey is a robust and reliable system with high-quality image output. Data processing can be upgraded with non-standard features added on request as shown in two examples: (1) the testing of splenectomy efficacy in the case of thrombocytopenia with normal production; and (2) the detection and localisation of parathyroid adenomas. © 2014 Elsevier Ltd. - Some of the metrics are blocked by yourconsent settings
Publication GammaKey system for improved diagnostics with gamma cameras(2014) ;Janković, Milica M. (36611860300) ;Pijetlović, Boris (56167841500) ;Marković, Ana Koljević (57198206230) ;Todorović-Tirnanić, Mila V. (12772684600) ;Beatović, Slobodanka Lj. (6507312377) ;Antić, Vojislav (55647858000) ;Odalović, Strahinja (57218390032) ;Sekulić, Stevan (56167436300) ;Jorgovanović, Nikola (24461567100)Popović, Dejan B. (7201969165)We designed the GammaKey system for the acquisition, storage and analysis of images from semi-analogue gamma scintillation cameras (GSCs). The GammaKey system, operating on a standard PC, replicates the functionality of earlier dedicated computer systems, allows the exchange of data in the DICOM format and has an open architecture enabling the development of new diagnostic techniques. The main purpose of the GammaKey is to enable the continued use of old GSCs which have functional scintillation crystals, but also to permit data exchange with new digital GSCs. The GammaKey has been technically validated by standards established by the National Electrical Manufacturers Association. The GammaKey has been used for seven years in two leading centres for nuclear medicine in Serbia (the Clinical Center of Serbia, Belgrade, and the Clinical Center of Vojvodina, Novi Sad) in approximately 30,000 patients. Clinical application proves that the GammaKey is a robust and reliable system with high-quality image output. Data processing can be upgraded with non-standard features added on request as shown in two examples: (1) the testing of splenectomy efficacy in the case of thrombocytopenia with normal production; and (2) the detection and localisation of parathyroid adenomas. © 2014 Elsevier Ltd. - Some of the metrics are blocked by yourconsent settings
Publication Interobserver reproducibility of mercaptoacetyltriglicine renography in children and adults with suspected obstruction: Parameters of drainage and function calculated by International Atomic Energy Agency software(2020) ;Radulović, Marija (56789775400) ;Janković, Milica M. (36611860300) ;Durutović, Otaš (6506011266) ;Šobić-Šaranović, Dragana P. (57202567582) ;Ajdinović, Boris (24167888800) ;Artiko, Vera M. (55887737000) ;Žeravica, Radmila (16320233000)Beatović, Slobodanka Lj. (6507312377)Objective The aim of this study was to estimate interobserver reproducibility of Tc-99m mercaptoacetyltriglycine renography in children and adults by assessing the parameters of the International Atomic Energy Agency (IAEA) software for the analysis of dynamic renal studies. Methods The renograms of 65 children and 65 adults covered a wide age range, different quality of drainage, overall function and differential renal function (DRF). Three observers were processing parameters of the IAEA software. Normalized residual activity at 20 min (NORA20), NORA on the postmicturition acquisition (NORApm), PM to maximum renal count ratio (PM/max), output efficiency at 20 min (OE20), OE 20 min after diuretic stimulation (OEF + 20), whole kidney mean transit time (MTT) and DRF by integral and Rutland-Patlak were calculated by observers. Results The overall agreement between three observers was almost perfect [the average intraclass correlation coefficient (ICC) above 0.99] in children and adults, with no significant difference between the parameters of renal drainage, transit and DRF. ICCs for all parameters were higher than 0.980 in children under 12 months, even slightly greater for PM/max and OEF+20. In children with poor/incomplete drainage and DRF below 40%, ICCs were above 0.98. In the subgroup of adults with impaired overall tubular extraction rate, level of reproducibility was almost perfect. Slightly lower but still insignificant values of ICC were presented in adults with poor/incomplete drainage. Conclusion Our results indicate an excellent interobserver reproducibility for all quantitative parameters of IAEA software in both pediatric and adult patients. © 2020 Lippincott Williams and Wilkins. All rights reserved.
