Repository logo
  • English
  • Srpski (lat)
  • Српски
Log In
Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "Antovic, Jovan P. (6701874787)"

Filter results by typing the first few letters
Now showing 1 - 4 of 4
  • Results Per Page
  • Sort Options
  • Loading...
    Thumbnail Image
    Some of the metrics are blocked by your 
    consent settings
    Publication
    Correlation to FVIII: C in two thrombin generation tests: TGA-CAT and INNOVANCE ETP
    (2017)
    Ljungkvist, Marcus (57193167894)
    ;
    Berndtsson, Maria (6603376446)
    ;
    Holmström, Margareta (7006841518)
    ;
    Mikovic, Danijela (35585598700)
    ;
    Elezovic, Ivo (12782840600)
    ;
    Antovic, Jovan P. (6701874787)
    ;
    Zetterberg, Eva (7801409763)
    ;
    Berntorp, Erik (55145811700)
    Introduction: Several thrombin-generation tests are available, but few have been directly compared. Our primary aim was to investigate the correlation of two thrombin generation tests, thrombin generation assay-calibrated automated thrombogram (TGA-CAT) and INNOVANCE ETP, to factor VIII levels (FVIII:C) in a group of patients with hemophilia A. The secondary aim was to investigate inter-laboratory variation for the TGA-CAT method. Methods: Blood samples were taken from 45 patients with mild, moderate and severe hemophilia A. The TGA-CAT method was performed at both centers while the INNOVANCE ETP was only performed at the Stockholm center. Correlation between parameters was evaluated using Spearman's rank correlation test. For determination of the TGA-CAT inter-laboratory variability, Bland-Altman plots were used. Results: The correlation for the INNOVANCE ETP and TGA-CAT methods with FVIII:C in persons with hemophilia (PWH) was r=0.701 and r=0.734 respectively. The correlation between the two methods was r=0.546. When dividing the study material into disease severity groups (mild, moderate and severe) based on FVIII levels, both methods fail to discriminate between them. The variability of the TGA-CAT results performed at the two centers was reduced after normalization; before normalization, 29% of values showed less than ±10% difference while after normalization the number increased to 41%. Conclusions: Both methods correlate in an equal manner to FVIII:C in PWH but show a poor correlation with each other. The level of agreement for the TGA-CAT method was poor though slightly improved after normalization of data. Further improvement of standardization of these methods is warranted.
  • Loading...
    Thumbnail Image
    Some of the metrics are blocked by your 
    consent settings
    Publication
    Does the intensity and quality of treatment and not only the factor VIII level influence global hemostasis in patients with hemophilia A?
    (2016)
    Berndtsson, Maria (6603376446)
    ;
    Zetterberg, Eva (7801409763)
    ;
    Holmström, Margareta (7006841518)
    ;
    Mahmoud Hourani Soutari, Nida (57189844583)
    ;
    Mikovic, Danijela (35585598700)
    ;
    Elezovic, Ivo (12782840600)
    ;
    Antovic, Jovan P. (6701874787)
    [No abstract available]
  • Loading...
    Thumbnail Image
    Some of the metrics are blocked by your 
    consent settings
    Publication
    Elevations in soluble CD40 ligand in patients with high platelet aggregability undergoing percutaneous coronary intervention
    (2009)
    Obradovic, Slobodan D. (6701778019)
    ;
    Antovic, Jovan P. (6701874787)
    ;
    Antonijevic, Nebojsa M. (6602303948)
    ;
    Ratkovic, Nenad G. (6506233469)
    ;
    Vojvodic, Danilo V. (6603787420)
    ;
    Subota, Vesna S. (16319788700)
    ;
    Gligic, Branko Lj (6701856883)
    ;
    Obradovic, Dragana V. (7005065235)
    ;
    Marinkovic, Eiena M. (26664824700)
    ;
    Wallen, Hakan N. (8898024900)
    High aggregatory responses despite antiplatelet treatment is associated with an increased risk of thrombotic complications following percutaneous coronary intervention (PCI). In the present study, we investigated the relationship between platelet aggregatory responses to ADP and the release of CD40L (sCD40L): an immunomodulatory compound involved in atherothrombosis - in patients undergoing PCI. ADP-induced platelet aggregation, sCD40L and soluble P-selectin (sP-selectin) were determined before and 24 h after PCI, in samples from 52 patients receiving aspirin and thienopyridines. Platelet aggregation to ADP above the median was defined as 'high aggregation', and aggregation below the median as 'low aggregation'. Data below are medians and interquartile ranges. Patients with 'high platelet aggregability' had a significantly higher increase in both SCD40L (A-values: 0.78 (-0.19-3.18) vs. -0.65 (-2.10-0.00) ng/ml, P= 0.002) and sP-selectin (A-values: 8.0 (-2.00-16.00) vs. 4.50 (-13.00-0.50) ng/ml, P = 0.001) compared with patients with 'low platelet aggregability'. In a multivariate linear regression analysis adjusted for clinical characteristics and type of preintervention therapy, the only independent predictors of sCD40L and sP-selectin were platelet aggregation to ADP before PCI (P< 0.001) and the combination of platelet aggregation to ADP before PCI and urgency of PCI (P< 0.001). Circulating CD40L is more markedly increased after PCI in patients with high ADP-induced platelet aggregation. Blood Coagul Fibrinolysis 20:283-289. © 2009 Wolters Kluwer Health | Lippincott Williams & Wilkins.
  • Loading...
    Thumbnail Image
    Some of the metrics are blocked by your 
    consent settings
    Publication
    Two global haemostatic assays as additional tools to monitor treatment in cases of haemophilia A
    (2012)
    Antovic, Jovan P. (6701874787)
    ;
    Mikovic, Danijela (35585598700)
    ;
    Elezovic, Ivo (12782840600)
    ;
    Holmström, Margareta (7006841518)
    ;
    Wilkens, Matthias (49864844200)
    ;
    Elfvinge, Petra (54789594700)
    ;
    Soutari, Nida Mahmoud Hourani (55308888900)
    ;
    Antovic, Aleksandra (6602938186)
    Haemophilia A patients with similar levels of factor VIII (FVIII) may have different bleeding phenotypes and responses to treatment with FVIII concentrate. Therefore, a test which determines overall haemostasis may be appropriate for treatment monitoring in some patients. We studied two global haemostatic methods: endogenous thrombin potential (ETP) and overall haemostatic potential (OHP) before and after injection of FVIII concentrate in patients with haemophilia A treated prophylactically and on-demand. A significant correlation between FVIII and both ETP and OHP was observed, while ETP and OHP differed between patients with severe and mild clinical phenotypes. Both ETP and OHP differed significantly between severe, moderate and mild haemophilia A and controls. ETP and OHP increased after intravenous injection of FVIII concentrate in both groups of patients, but in spite of higher pre-treatment values of both ETP and OHP in patients treated prophylactically, and much higher post-treatment FVIII levels in comparison with the values in patients treated on-demand, no difference after treatment was observed for either ETP or OHP. ETP and OHP may be additional alternatives for monitoring (and even for individual tailoring) treatment in patients with haemophilia A. © Schattauer 2012.

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Privacy policy
  • End User Agreement
  • Send Feedback