Browsing by Author "Andrea, Antonello D'. (57203971767)"
Now showing 1 - 1 of 1
- Results Per Page
- Sort Options
- Some of the metrics are blocked by yourconsent settings
Publication Quality control of B-lines analysis in stress Echo 2020(2018) ;Scali, Maria Chiara (55929478400) ;Ciampi, Quirino (6602299243) ;Picano, Eugenio (7102408994) ;Bossone, Eduardo (55238465000) ;Ferrara, Francesco (57201099810) ;Citro, Rodolfo (15921921800) ;Colonna, Paolo (57221823607) ;Costantino, Marco Fabio (55499164600) ;Cortigiani, Lauro (55663049600) ;Andrea, Antonello D'. (57203971767) ;Severino, Sergio (7006690054) ;Dodi, Claudio (6602478787) ;Gaibazzi, Nicola (6603190525) ;Galderisi, Maurizio (57203882101) ;Barbieri, Andrea (56377673100) ;Monte, Ines (55884115100) ;Mori, Fabio (24290552500) ;Reisenhofer, Barbara (6603491191) ;Re, Federica (57210067725) ;Rigo, Fausto (6701803166) ;Trambaiolo, Paolo (6602701604) ;Amor, Miguel (37066931100) ;Lowenstein, Jorge (7103408229) ;Merlo, Pablo Martin (57191339958) ;Daros, Clarissa Borguezan (57192979152) ;De Castro E Silva Pretto, José Luis (6508318426) ;Miglioranza, Marcelo Haertel (35956952500) ;Torres, Marco A. R. (7402581476) ;De Azevedo Bellagamba, Clarissa Carmona (57194341124) ;Chaves, Daniel Quesada (57218502925) ;Simova, Iana (23391267500) ;Varga, Albert (7102315827) ;Čelutkiene, Jelena (6507133552) ;Kasprzak, Jaroslaw D. (35452933600) ;Wierzbowska-Drabik, Karina (12772110800) ;Lipiec, Piotr (6602351463) ;Weiner-Mik, Paulina (6603038461) ;Szymczyk, Eva (25121768000) ;Wdowiak-Okrojek, Katarzyna (44261600800) ;Djordjevic-Dikic, Ana (57003143600) ;Dekleva, Milica (56194369000) ;Stankovic, Ivan (57197589922) ;Neskovic, Aleksandar N. (35597744900) ;Zagatina, Angela (22939399700) ;Di Salvo, Giovanni (7003610825) ;Perez, Julio E. (7403417846) ;Camarozano, Ana Cristina (14055534600) ;Corciu, Anca Irina (26024616600) ;Boshchenko, Alla (6602887127) ;Lattanzi, Fabio (7005850087) ;Cotrim, Carlos (12767342300) ;Fazendas, Paula (6602151601) ;Haberka, Maciej (22834420800) ;Sobkowic, Bozena (57203972291) ;Kosmala, Wojciech (7004641258) ;Witkowski, Tomasz (7003737196) ;Gosciniak, Piotr (6507268076) ;Salustri, Alessandro (36943779100) ;Rodriguez-Zanella, Hugo (56109055800) ;Leal, Luis Ignacio Martin (57203967299) ;Nikolic, Alexandra (59432908700) ;Gligorova, Suzana (11840443000) ;Urluescu, Madalina-Loredana (57203972404) ;Fiorino, Maria (56368246800) ;Novo, Giuseppina (56962711700) ;Preradovic-Kovacevic, Tamara (59158416100) ;Ostojic, Miodrag (34572650500) ;Beleslin, Branko (6701355424) ;Villari, Bruno (6701632106) ;De Nes, Michele (6507042094) ;Paterni, Marco (7003660393) ;Carpeggiani, Clara (7003751506)Andreassi, Maria Grazia (7004571465)Background: The effectiveness trial "Stress echo (SE) 2020" evaluates novel applications of SE in and beyond coronary artery disease. The core protocol also includes 4-site simplified scan of B-lines by lung ultrasound, useful to assess pulmonary congestion. Purpose: To provide web-based upstream quality control and harmonization of B-lines reading criteria. Methods: 60 readers (all previously accredited for regional wall motion, 53 B-lines naive) from 52 centers of 16 countries of SE 2020 network read a set of 20 lung ultrasound video-clips selected by the Pisa lab serving as reference standard, after taking an obligatory web-based learning 2-h module (http://se2020.altervista.org). Each test clip was scored for B-lines from 0 (black lung, A-lines, no B-lines) to 10 (white lung, coalescing B-lines). The diagnostic gold standard was the concordant assessment of two experienced readers of the Pisa lab. The answer of the reader was considered correct if concordant with reference standard reading ±1 (for instance, reference standard reading of 5 B-lines; correct answer 4, 5, or 6). The a priori determined pass threshold was 18/20 (≥ 90%) with R value (intra-class correlation coefficient) between reference standard and recruiting center) > 0.90. Inter-observer agreement was assessed with intra-class correlation coefficient statistics. Results: All 60 readers were successfully accredited: 26 (43%) on first, 24 (40%) on second, and 10 (17%) on third attempt. The average diagnostic accuracy of the 60 accredited readers was 95%, with R value of 0.95 compared to reference standard reading. The 53 B-lines naive scored similarly to the 7 B-lines expert on first attempt (90 versus 95%, p = NS). Compared to the step-1 of quality control for regional wall motion abnormalities, the mean reading time per attempt was shorter (17 ± 3 vs 29 ± 12 min, p <.01), the first attempt success rate was higher (43 vs 28%, p < 0.01), and the drop-out of readers smaller (0 vs 28%, p <.01). Conclusions: Web-based learning is highly effective for teaching and harmonizing B-lines reading. Echocardiographers without previous experience with B-lines learn quickly. © 2018 The Author(s).