Browsing by Author "Štimec, B.V. (7003411337)"
Now showing 1 - 3 of 3
- Results Per Page
- Sort Options
- Some of the metrics are blocked by yourconsent settings
Publication Arterial supply of the trigeminal ganglion, a micromorphological study(2020) ;Ćetković, M. (9232864300) ;Štimec, B.V. (7003411337) ;Mucić, D. (57215786002) ;Dožić, A. (56436393400) ;Ćetković, D. (57192720059) ;Reçi, V. (57209302995) ;Çerkezi, S. (57204287580) ;Ćalasan, D. (36960892200) ;Milisavljević, M. (6701873424)Bexheti, S. (25623269900)Background: In this study, we explored the specific microanatomical properties of the trigeminal ganglion (TG) blood supply and its close neurovascular relationships with the surrounding vessels. Possible clinical implications have been discussed. Materials and methods: The internal carotid and maxillary arteries of 25 adult and 4 foetal heads were injected with a 10% mixture of India ink and gelatin, and their TGs subsequently underwent microdissection, observation and morphometry under a stereoscopic microscope. Results: The number of trigeminal arteries varied between 3 and 5 (mean 3.34), originating from 2 or 3 of the following sources: the inferolateral trunk (ILT) (100%), the meningohypophyseal trunk (MHT) (100%), and from the middle meningeal artery (MMA) (92%). In total, the mean diameter of the trigeminal branches was 0.222 mm. The trigeminal branch of the ILT supplied medial and middle parts of the TG, the branch of the MHT supplied the medial part of the TG, and the branch of the MMA supplied the lateral part of the TG. Additional arteries for the TG emerged from the dural vascular plexus and the vascular network of the plexal segment of the trigeminal nerve. Uniform and specific intraganglionic dense capillary network was observed for each sensory trigeminal neuron. Conclusions: The reported features of the TG vasculature could be implied in a safer setting for surgical approach to the skull base, in relation to the surrounding structures. The morphometric data on TG vasculature provide anatomical basis for better understanding the complex TG blood supply from the internal and external carotid arteries. Copyright © 2020 Via Medica - Some of the metrics are blocked by yourconsent settings
Publication The superficial palmar branch of the radial artery: A corrosion cast study(2018) ;Ilić, M. (36571854100) ;Milisavljević, M. (6701873424) ;Maliković, A. (9741953000) ;Laketić, D. (25936376800) ;Erić, D. (57194424430) ;Boljanović, J. (57193680750) ;Dožić, A. (56436393400) ;Štimec, B.V. (7003411337)Manojlović, R. (19933967900)Background: Surgical procedures such as thenar flaps and radial artery (RA) harvesting call for an elaborate anatomical study of the RA's superficial palmar branch (SPB). The aim of this study was to describe the branching pattern of this vessel related to the morphometric characteristics and variations of this artery. Materials and methods: Twenty 4% formalin solution-injected hands were dissected. For the morphometric study we used another group of 35 human hands of adult persons, injected with methyl methacrylate fluid into the ulnar and radial arteries. As soon as polymerisation was completed, a 40% solution of potassium hydroxide was applied for corrosion. The vascular arterial casts were examined under the stereoscopic microscope and precise drawings of each specimen were made. Results: In the majority of cases (75%) SPB passed superficially, over the abductor pollicis brevis muscle. The mean diameter of the SPB, very variable depending on its length and field of supply, was 1.52 ± 0.49 mm, ranging from 0.8 to 2.7 mm. Developed SPB type, was present in 31.4% of hands, with the diameter of 1.7 mm and larger (mean 1.95 mm), continuing distally to become the radialis indicis artery, with an average calibre of 1.2 mm, and with important branches to the thumb. In most hands (68.6%), the hypoplastic SPB, was present, with a mean diameter of 1.17 mm, and the field of supply within the thenar area. Conclusions: Knowledge of the SPB dominance and existence of anastomotic vessels in its field of supply are of importance to avoid the risk of possible ischaemic sequelae in the hand associated with harvesting the RA. Copyright © 2018 Via Medica. - Some of the metrics are blocked by yourconsent settings
Publication Vascular anatomy of the thenar eminence: Its relevance to a pedicled or free thenar flap(2017) ;Zekavica, A. (57194423133) ;Milisavljević, M. (6701873424) ;Erić, D. (57194424430) ;Ćurčić, B. (57194424715) ;Popović, S. (57194427238) ;Vitošević, B. (9232864400) ;Dožić, A. (56436393400) ;Štimec, B.V. (7003411337)Manojlović, R. (19933967900)Background: The aim of this study was to clarify the arterial supply of the skin covering the prominent part of the thenar eminence in order to describe the possibility and potential for harvesting a pedicled or a free flap from the thenar eminence. Materials and methods: The arteries were studied in 30 post-mortem specimens of human hands; 3 previously perfused with 4% formaldehyde solution, and injected with black India ink, and 27 injected with methyl-methacrylate and afterwards corroded in 40% potassium hydroxide solution. Results: In all hands we found two little palmar arteries coming from the anatomical snuff-box portion of the radial artery. We labelled the first (proximal) branch as the middle thenar artery, because it supplies the middle third of the thenar eminence skin. Its diameter varied from 0.25 to 0.55 mm (mean 0.4 mm). The distal, more prominent branch of the radial artery, vascularised the lateral third of the thenar eminence skin, and was named the lateral thenar artery; its diameter ranged from 0.40 to 0.90 mm (mean 0.67 mm). The superficial palmar branch of the radial artery, always present, was classified as: hypoplastic, average or prominent, with a diameter ranging from 0.8 to 2.7 mm (mean 1.47 mm). Conclusions: Three individually developed branches of the radial artery supplied the skin of the thenar eminence. Cutaneous branches of these three arteries were interconnected via anastomotic vessels. Copyright © 2017 Via Medica.
